Correspondence: [*] Corresponding author: Xiangchao Li, Key Laboratory for Aerosol-Cloud-Precipitation of China Meteorological Administration, Collaborative Innovation Center on Forecast and Evaluation of Meteorological Disasters, School of Atmospheric Physics, Nanjing University of Information Science and Technology, 210044 Nanjing, China. E-mail: 000420@nuist.edu.cn.
Abstract: Lightning overvoltage may affect the signal transmission and damage terminal equipment. In order to solve this problem, the signal system Surge Protection Devices (SPDs) is designed by analyzing the signal transmission characteristic and the design theory of SPDs. The impulse tests are performed on the SPDs using a combined wave generator. Residual voltages and sharing currents are measured and discussed by considering impulse voltages, DC breakdown voltages of downstream SPDs and decoupling resistances. The blind zone of the signal system SPDs is also discussed in detail. In addition, the SPDs are equivalent to a two-port network, and the influence of distributed capacitance of the SPDs on signal transmission is analyzed for the first time through experiments. Cut-off frequency is measured and discussed by considering DC breakdown voltages of downstream SPDs and decoupling resistances. From the two experiments, the results indicate that increasing the decoupling resistance can decrease residual voltage and sharing current, but will reduce the cut-off frequency. Decreasing the DC voltage of downstream SPDs will have a similar effect. So the decoupling resistance and the DC breakdown voltage of downstream SPDs resistance need to be considered carefully in designing signal system SPDs. The sufficient research of signal system SPDs in this paper has a certain reference value in lightning protection.
Keywords: Signal system SPDs, blind zone, sharing current, residual voltage, transmission characteristic, lightning protection
DOI: 10.3233/JAE-170069
Journal: International Journal of Applied Electromagnetics and Mechanics, vol. 56, no. 4, pp. 559-571, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl