Abstract: Permanent magnet is the key component of nuclear magnetic resonance (NMR) instrument. Based on the principle of Halbach array, this study designs and optimizes a multilayer Halbach permanent magnet for human finger NMR detection. The quality factor (QF) is introduced to represent the performance of magnetic field, firstly. The impact on magnetic performance, caused by various magnet heights, is analyzed using Finite Element Method (FEM). In order to compensate the end effect, the radial adjustment method is proposed, combining the adjustments of the radial size and the radial position of the magnet blocks. Comparing the effect on magnetic field of three different plans, the results show that combining the adjustments of inner radius and outer radius shims the field dramatically. Finally the designed construction is stacked by 11 layers of magic rings and each layer is composed of 8 trapezoid-shaped magnets. The magnetic field of the center cylindrical region (ϕ20 × 20 mm) of the structure is calculated, whose final strength achieves up to 447 mT and homogeneity is within 500 ppm. The designed magnet structure is manufactured and the measurement is finished in the end. The proposed construction has the advantages of small size and high uniformity, which has an extensive application prospect in portable NMR system.
Keywords: NMR, permanent magnet, Halbach array, multilayer, radial adjustment
DOI: 10.3233/JAE-160101
Journal: International Journal of Applied Electromagnetics and Mechanics, vol. 54, no. 3, pp. 315-327, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl