Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Subtitle:
Article type: Research Article
Authors: Lee, Min Younga | Yi, Yeo-Jeena | Park, Hanaroa | Kim, Mi Heea | Lee, Jun Hob | Oh, Seung-Hab | Suh, Myung-Whana; *
Affiliations: [a] Department of Otorhinolaryngology-Head & Neck Surgery, Seoul National University Hospital, Seoul, Korea | [b] Department of Otorhinolaryngology-Head & Neck Surgery, Seoul National University College of Medicine, Sensory Organ Research Institute, Seoul National University Biomedical Research Institute, Seoul, Korea
Correspondence: [*] Corresponding author: Myung-Whan Suh, Department of Otorhinolaryngology-Head & Neck Surgery, Seoul National University Hospital, Seoul, Korea. Tel.: +82 2 2072 4845; Fax: +82 2 766 2447; E-mail:drmung@naver.com
Abstract: AIMS: The purpose of this study is to compare the test-retest reliability of cervical vestibular evoked myogenic potential (cVEMP) parameters between monaural sequential (mSEQ) cVEMP and binaural simultaneous (bSIM) cVEMP recordings. MATERIALS AND METHODS: Twenty two volunteers aged 22 from 38 years were enrolled. Two different methods of cVEMP measurement were performed in the subjects. The two methods were (1) monaural sequential (mSEQ) measurement and (2) binaural simultaneous (bSIM) measurement. After a mean test-retest interval of 7.1 ± 2.8 days, the second run of the cVEMP measurement was performed in a random order. To compare the test-retest reliability of mSEQ and bSIM cVEMP responses, Intraclass correlation coefficient (ICC) and Spearman correlation were applied. RESULTS: Both p13 and n23 latencies did not show a statistically significant difference between the two cVEMP recording methods. Also, there were no significant differences in the inter-peak amplitude (IPA) and interaural amplitude difference (IAD) ratio between the two methods. The test-retest reliability of inter-peak amplitude (IPA) demonstrated a positive correlation for both mSEQ and bSIM cVEMP methods. The IAD ratio of bSIM cVEMP response demonstrated a statistically significant test-retest reliability (ICC = 0.691, p= 0.015). However, the IAD ratio of mSEQ cVEMP response did not demonstrate a statistically significant test-retest correlation. CONCLUSION: Results implicate that bSIM cVEMP not only saves time, but it also has an advantage of a more reliable test-retest outcome.
Keywords: cVEMP, VEMP, bilateral, reliability
DOI: 10.3233/VES-150560
Journal: Journal of Vestibular Research, vol. 25, no. 3-4, pp. 151-160, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl