Abstract: Fault detection and identification in a solar Photovoltaic (PV) systems are one of the crucial task in recent days for ensuring both reliability and safety measures. The fault occurrence in the PV cell will affect the output power, and can reduce the efficiency of its characteristics. The fault in PV cell can identify by using the thermal scan method manually. Arrangement of the proposed setup regularly is not possible to monitor due to the hardware installation of several equipment, it took more time to test, and validate the affected PV cells prediction less accuracy while doing in manual testing. In order to solve these issues, this paper intends to propose a novel algorithm, named as Truncated Arrangement of Active Cell (TAAC) structure for accurately detecting the PV faults. This technique is used to analyze the PV cell aging condition and to enhance the PV characteristics. Typically, the improvement in a cell arrangement provides an optimal solution for efficient fault detection. Moreover, the TAAC architecture computes the optimal solution for a PV output terminal based on the PV cell parameters and variation of temperature measures. Also, a Kalman filtering technique is employed to extract the features that are used to improve the detection process. The major advantages of this structure are, it enhance the lifetime of PV cell and stores the maximum power for a long time usage. The experimental results evaluate the performance of this technique by using various measures such as false alarm rate, misclassification rate, misdetection rate, and prediction rate. Furthermore, some of the existing techniques are compared with the proposed technique for proving its superiority.
Keywords: Renewable Energy Source (RES), Photovoltaic (PV), fault detection, Truncated Arrangement of Active Cell (TAAC), Maximum Power Point Tracking (MPPT)
DOI: 10.3233/JIFS-213040
Journal: Journal of Intelligent & Fuzzy Systems, vol. 43, no. 3, pp. 2549-2565, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl