Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Purchase individual online access for 1 year to this journal.
Price: EUR 150.00Authors: Lu, Weijia | Yan, Zhuangzhi
Article Type: Research Article
Abstract: BACKGROUND: Bronchitis is considered a non-specific inflammation in the peripheral tissues of the trachea and bronchus. Many therapeutic schemes for chronic bronchitis have been reported in existing research. METHODS: This work attempted to conduct optimization analysis of the therapeutic scheme for chronic bronchitis using a data mining method. To overcome the shortfalls of the current fuzzy C-means clustering (FCM) algorithm, this research proposed an improved kernel fuzzy C-means (KFCM) clustering algorithm. The improved KFCM algorithm solved traditional cluster algorithm problems in two ways: firstly FCM clustering was mapped in high-dimensional kernel space; and the samples …in the initial input space R^S were mapped to high-dimensional feature space R^p. Finally, the improved and traditional algorithms by computer simulation experiments. RESULTS: Based on the analysis of the simulation experiments on IRIS dataset in this research, improved KFCM algorithm could improve calculation accuracy by 10% because the initial value greatly decreased the number of iterations and improved the accuracy of the calculation. CONCLUSION: The improved KFCM algorithm was used to optimize the relationship between data structures in the process of iteration clustering so as to accelerate iteration convergence. The simulation results show that the improved KFCM algorithm performs better in terms of both calculating performance and clustering correctness. Show more
Keywords: Data mining, chronic bronchitis, KFCM algorithm, medical information
DOI: 10.3233/THC-151023
Citation: Technology and Health Care, vol. 23, no. 6, pp. 699-713, 2015
Authors: Nagao, Mitsuo | Konno, Shin-ichi | Kim, Young Ho | Yokota, Osamu
Article Type: Research Article
Abstract: BACKGROUND: Elderly people are often affected by age-related knee osteoarthritis (KOA). The development of sensors for measuring and diagnostic devices used in preventive healthcare of that illness therefore constitutes an urgent issue. OBJECTIVE: After developing a bone joint acoustic sensor (BJAS) that receives signals of mechanical vibrations in the knee joints during bending and stretching motions, we tested it and compared responses with those of an acceleration sensor used as a reference. METHODS: For six examinees in their 20 s, using an acceleration sensor as a reference for comparison with BJAS, we …conducted two frequency-response tests of impact excitation and knee bending and stretching. For impact excitation tests, two transmission systems of hard materials and soft materials were applied. We examined the cross spectral density, coherence function, Fourier transform and quantified signal. RESULTS: Although BJAS detected signals of 0.5-15.0 kHz in impact excitation tests, considerably strong damping was found for soft specimens at higher frequencies. Therefore, acceleration sensors showed superiority over BJAS for impact excitation. However, for knee bending and stretching, BJAS detected signal frequencies of 0.5-8.0 kHz for all six examinees. BJAS demonstrated marked superiority over the acceleration sensor. Furthermore, we were able to quantify the signal intensity for each frequency for comparison. CONCLUSIONS: The BJAS frequency response was superior to that of the acceleration sensor for capturing signals from knee bending and stretching. This superiority suggests its promise for application to clarify mechanical signals from knees. Show more
Keywords: Bone joint, acoustic sensor, frequency response, short time Fourier transform (STFT), coherence, impact excitation method, pig skin, knee joint
DOI: 10.3233/THC-151024
Citation: Technology and Health Care, vol. 23, no. 6, pp. 715-727, 2015
Authors: Zhang, Melvyn W.B. | Ho, Roger C.M. | Hawa, Raed | Sockalingam, Sanjeev
Article Type: Research Article
Abstract: BACKGROUND: The respective rates of obesity in Canada and the United states are estimated to be 24.1% and 34.1%. Due to the increased incidence of obesity, Bariatric surgery has been recognized as one of the treatment options. Patients who have undergone Bariatric surgery tend to need chronic long-term follow-up with a multi-disciplinary team. In the past decade, there has been massive advancemcent and development in Internet, Web-based and Smartphone technologies. However, there seemed to be a pacuity of applications in this area that enables post-bariatric patients to self-manage their own condition. In addition, past research have highlighted the …limited evidence based with regards to currently available bariatric applications, mainly due to the lack of medical professionals involvement. OBJECTIVE: Our current research objective is to illustrate the development of a Bariatric After-care smartphone application and to highlight user preferences with regards to the features integrated within the application. METHODOLOGY: The Bariatric Aftercare application was developed between the months of March 2014 to April 2014. Making use of low-cost online web-based application developmental technologies, the authors embarked on the development of the web-based application. Patients who attended their routine follow-up appointments are given the links to the web-based application. They were also recruited to participate in an online user evaluation survey to identify their preferences with regards to the features integrated. RESULTS: Since the inception of the web-based application to date, there has been a cumulative total of 385 unique assess to the online web-based application. There is a slight change in the confidence levels of the participants with regards to using the application to help them self-manage their own condition. The majority of the users have indicated that they preferred the information pertaining to what happens during each consult with members of the multidisciplinary team and also greatly valued the feature with regards to the ability to re-schedule their appointments. The vast majority also found the additional resources to be helpful. CONCLUSIONS: This is one of the first studies to demonstrate the potential use of smartphone innovations in Bariatric After-care self-management. The current study has shown that users are generally receptive towards such an innovative implementation and has also highlighted some of their preferences with regards to such a self-management application for self-management of their health condition post bariatric surgery. In addition, the authors have also managed to demonstrate how clinicians could be involved in the formulation of a bariatric care application, which has an evidence base. Show more
Keywords: Bariatric surgery, obesity, chronic disease management, technology, clinical management, smartphone, mobile phones, smartphone applications
DOI: 10.3233/THC-151025
Citation: Technology and Health Care, vol. 23, no. 6, pp. 729-736, 2015
Authors: Zhang, Melvyn W.B. | Ho, Roger C.M. | Cassin, Stephanie E. | Hawa, Raed | Sockalingam, Sanjeev
Article Type: Research Article
Abstract: BACKGROUND: The respective rates of obesity in Canada and the United states are estimated to be 24.1% and 34.1%. Due to the increased incidence of obesity, Bariatric surgery has been recognized as one of the treatment options. Despite the success of Bariatric surgery, studies have proposed that it has neglected the contributions of other factors, such as psychological factors in the causation as well as the maintenance of obesity amongst individuals. Cognitive behavioral therapy (CBT) is largely a psychosocial intervention that has been shown to be efficacious, as studies have demonstrated that even brief CBT interventions could help …in the reduction of binge eating and maintenance of weight loss. Previously identified problems with regards to the integration and the provision of such interventions include that of geographical barriers. In order to overcome the geographical barriers, telephone-based CBT has been conceptualized. Over the past decade, there has been massive advancement and development in Internet, Web-based and smartphone technologies, but there is still a paucity of applications in this area. OBJECTIVE: Our current research objective is to determine if bariatric surgery patients will be receptive towards an online and smartphone based CBT intervention. METHODOLOGY: The Bariatric Surgery Online CBT portal and Smartphone companion application was developed between July 2013 and December 2013. A low-cost methodology of developing the online portal was adopted. In terms of development, 4 core development phases were adopted. These included that of: a) Formulation of users' requirements, b) System design and development, c) System evaluation and d) System deployment and pilot application. The bariatric surgery workgroup from the Toronto Western Hospital helped with the recruitment of the subjects from the outpatient specialist service. Links to the web-portal was provided to each of the participants recruited. RESULTS: Since the inception of the online portal to date, in terms of usage rates, there have been a total of 2408 visitors to the online portal. The majority of the visitors are from Canada (n= 1879). From the analytics, a total of 8 users have participated in the pre-assessment questionnaire and have attempted and tried to use the individual modules. Since the inception of the pilot study from January 2014 till October 2014, 4 individuals have completed at least 3 modules available on the online portal. CONCLUSIONS: This is one of the first few studies that have demonstrated the potential feasibility of having an online and smartphone cognitive behavioral portal to serve the psychological needs of bariatric surgery patients. Show more
Keywords: Bariatric psycho-social care, CBT, online interventions, smartphone, psychiatry
DOI: 10.3233/THC-151026
Citation: Technology and Health Care, vol. 23, no. 6, pp. 737-744, 2015
Authors: Robertson, Kayela | Rosasco, Cody | Feuz, Kyle | Schmitter-Edgecombe, Maureen | Cook, Diane
Article Type: Research Article
Abstract: BACKGROUND: While advancements in technology have encouraged the development of novel prompting systems to support cognitive interventions, little research has evaluated the best time to deliver prompts, which may impact the effectiveness of these interventions. OBJECTIVE: This study examined whether transition-based context prompting (prompting an individual during task transitions) is more effective than traditional fixed time-based prompting. METHODS: Participants were 42 healthy adults who completed 12 different everyday activities, each lasting 1-7 minutes, in an experimental smart home testbed and received prompts to record the completed activities from an electronic memory notebook. …Half of the participants were delivered prompts during activity transitions, while the other half received prompts every 5 minutes. Participants also completed Likert-scale ratings regarding their perceptions of the prompting system. RESULTS: Results revealed that participants in the transition-based context prompting condition responded to the first prompt more frequently and rated the system as more convenient, natural, and appropriate compared to participants in the time-based condition. CONCLUSIONS: Our findings suggest that prompting during activity transitions produces higher adherence to the first prompt and more positive perceptions of the prompting system. This is an important finding given the benefits of prompting technology and the possibility of improving cognitive interventions by using context-aware transition prompting. Show more
Keywords: Prompting technology, cognitive intervention, assistive technology, cognitive aids
DOI: 10.3233/THC-151033
Citation: Technology and Health Care, vol. 23, no. 6, pp. 745-756, 2015
Authors: Radovic, Milos | Milosevic, Marina | Ninkovic, Srdjan | Filipovic, Nenad | Peulic, Aleksandar
Article Type: Research Article
Abstract: BACKGROUND: Reading mammograms is a difficult task and for this reason any development that may improve the performance in breast cancer screening is of great importance. OBJECTIVE: We proposed optimized computer aided diagnosis (CAD) system, equipped with reliability estimate module, for mass detection on digitized mammograms. METHODS: Proposed CAD system consists of four major steps: preprocessing, segmentation, feature extraction and classification. We propose a simple regression function as a threshold function for extraction of potential masses. By running optimization procedure we estimate parameters of the preprocessing and segmentation steps thus ensuring maximum mass …detection sensitivity. In addition to the classification, where we tested seven different classifiers, the CAD system is equipped with reliability estimate module. RESULTS: By performing segmentation 91.3% of masses were correctly segmented with 4.14 false positives per image (FPpi). This result is improved in the classification phase where, among the seven tested classifiers, multilayer perceptron neural network achieved the best result including 77.4% sensitivity and 0.49 FPpi. CONCLUSION: By using the proposed regression function and parameter optimization we were able to improve segmentation results comparing to the literature. In addition, we showed that CAD system has high potential for being equipped with reliability estimate module. Show more
Keywords: Breast cancer, computer-assisted image processing, data mining, mammography, optimization
DOI: 10.3233/THC-151034
Citation: Technology and Health Care, vol. 23, no. 6, pp. 757-774, 2015
Authors: Alam, Khurshid | Khan, Mushtaq | Muhammad, Riaz | Qamar, Sayyad Zahid | Silberschmidt, Vadim V.
Article Type: Research Article
Abstract: BACKGROUND: Bone drilling is a common practice of surgical treatments in orthopaedics and traumatology. Penetration of a high-speed drill into bone tissue is accompanied by generation of a significant amount of heat. Cooling of the drilling region is necessary to avoid potential risk of thermal damage to bone. OBJECTIVE: The purpose of this study was to measure and predict bone temperature by conducting experiments and numerical simulations using cooling by means of irrigation at two different temperatures. METHODS: A series of experiments and numerical studies were performed to investigate the effect of cooling …conditions on the rise in bone temperature in drilling. The temperature increase in bone was assessed for different drilling speeds and feed rates in the presence irrigation at 5°C and 25°C. RESULTS: Bone temperature was found to be strongly affected by the drilling parameters and cooling conditions. Irrigation with water at 5°C kept bone temperature well below the thermal threshold level. CONCLUSION: This study strongly recommends the use of irrigation at lower temperature for safe surgical incision. Show more
Keywords: Orthopaedic, bone drilling, experimental analysis, FE modelling, thermal necrosis
DOI: 10.3233/THC-151035
Citation: Technology and Health Care, vol. 23, no. 6, pp. 775-783, 2015
Authors: Suresh, R. | Bhalla, S. | Hao, J. | Singh, C.
Article Type: Research Article
Abstract: BACKGROUND: High importance is given to plantar pressure monitoring in the field of biomedical engineering for the diagnosis of posture related ailments associated with diseases such as diabetes and gonarthrosis. OBJECTIVE: This paper presents the proof-of-concept development of a new high resolution plantar pressure monitoring pad based on fiber Bragg grating (FBG) sensors. METHODS: In the proposed configuration, the FBG sensors are embedded within layers of carbon composite material (CCM) in turn conforming to an arc shape. A total of four such arc shaped sensors are instrumented in the pad at the locations …of the forefoot and the hind foot. As a test of the pad, static plantar pressure is monitored on normal subjects under various posture conditions. The pad is evaluated both as a standalone platform as well as a pad inserted inside a standard shoe. RESULTS: An average pressure sensitivity of 1.2 pm/kPa and a resolution of approximately 0.8 kPa is obtained in this special configuration. The pad is found to be suitable in both configurations- stand-alone pad as well as an insert inside a standard shoe. CONCLUSION: The proposed set up offers a cost-effective high resolution and accurate plantar pressure measurement system suitable for clinical deployment. The novelty of the developed pressure pad lies in its ability to be used both as platform type as well as inserted in-sole type sensor system. Show more
Keywords: Fibre-Bragg grating (FBG), pressure, diabetic foot, plantar pressure, pressure monitoring pad, in-sole
DOI: 10.3233/THC-151038
Citation: Technology and Health Care, vol. 23, no. 6, pp. 785-794, 2015
Authors: Pallavicini, Federica | Pedroli, Elisa | Serino, Silvia | Dell'Isola, Andrea | Cipresso, Pietro | Cisari, Carlo | Riva, Giuseppe
Article Type: Research Article
Abstract: BACKGROUND: Unilateral Spatial Neglect, or neglect, is a common behavioral syndrome in patients following unilateral brain damage, such as stroke. In recent years, new technologies, such as computer-based tools and virtual reality have been used in order to solve some limitations of the traditional neglect evaluation. Within this perspective, also mobile devices such as tablets seems to be promising tools, being able to support interactive virtual environments and, at the same time, allowing to easily reproduce traditional paper-and-pencil test. OBJECTIVE: In this context, the aim of our study was to investigate the potentiality of a new …mobile application (Neglect App) designed and developed for tablet (iPad) for screening neglect symptoms. METHODS: To address this objective, we divided a sample of 16 right-damaged patients according to the presence or absence of neglect and we administered assessment test in their traditional and Neglect App version. RESULTS: Results showed that the cancellation tests developed within Neglect App were equally effective to traditional paper-and-pencil tests (Line cancellation test and Star Cancellation test) in detecting neglect symptoms. Secondly, according to our results, the Neglect App Card Dealing task was more sensitive in detecting neglect symptoms than traditional functional task. CONCLUSIONS: Globally, results gives preliminary evidences supporting the feasibility of Neglect App for the screening of USN symptoms. Show more
Keywords: Neglect, neuropsychological assessment, tablet, virtual reality
DOI: 10.3233/THC-151039
Citation: Technology and Health Care, vol. 23, no. 6, pp. 795-807, 2015
Authors: Koutras, Christos | Bitsaki, Marina | Koutras, Georgios | Nikolaou, Christos | Heep, Hansjoerg
Article Type: Review Article
Abstract: BACKGROUND: e-Health is a widespread healthcare practice in the medical community, supported by technology-based applications aiming to deliver health services in an efficient manner, improving the quality of life and providing a wide range of health and socio-economic benefits to patients. OBJECTIVE: To investigate the use of e-Health and mobile applications for the follow-up of major joint arthroplasty patients and the socio-economic impact of e-Health services on arthroplasty patients. METHODS: Studies published after 2000 in English language, enrolling patients who underwent total knee or hip replacement, applying e-Health solutions and highlighting the economic …benefits obtained by patients, doctors and healthcare systems were considered for inclusion in the present study. RESULTS: Five studies satisfied our inclusion criteria and were included in qualitative analysis. In this paper, the use of e-Health for the follow-up of major joint arthroplasty patients and the positive impact in terms of cost, time and hospital visits reduction by applying e-Health solutions on arthroplasty patients are reviewed in detail as reported in the included studies. CONCLUSION: The majority of the included studies reported a positive impact in terms of cost, time and hospital visits reduction. Show more
Keywords: Arthroplasty, cost effectiveness, e-Health, healthcare, telemedicine
DOI: 10.3233/THC-151036
Citation: Technology and Health Care, vol. 23, no. 6, pp. 809-817, 2015
Authors: Mehmood, Seemab | Ali, Murtaza Najabat | Ansari, Umar | Mir, Mariam | Khan, Munezza Ata
Article Type: Research Article
Abstract: INTRODUCTION: Injuries cover about 11% of World's Disease Burden depicting fractures to be the leading severe consequence of trauma. Fractures occur due to force impact or osteoporosis. Fracture healing is a complicated process. Fracture fixation techniques focus on imparting reduction to fractured fragments and induce healing. When considering possible fixation methods, the aspect of micro-movement is an important one, as this induces callus formation which tends to be a crucial step for fracture healing. Internal fixation of long bone fractures using metallic plates has been carried out since decades and recently advancements have …been in synthesizing biodegradable plates as well. The purpose of this research was to fabricate an Auxetic Polymeric Bone Plate that can be used as an internal fixator for long bone fracture; this bone plate renders micro-movement due to its counter intuitive behavior, has the potential to reduce the effect of stress shielding and allow the same range of motion as that of natural bone. METHODS: Polyurethane was chosen as a material for the fabrication of the Auxetic device because of its biocompatibility and non-toxic effects. The plate was then tested for mechanical properties such as Tensile and Compression testing to determine the strength. RESULTS AND DISCUSSION: The tensile testing of the Auxetic polyurethane specimens showed that the mean of the Poisson's ratio of the samples lies between -0.68 and -0.87 at different uni-axial tensile load values. The Auxetic structure of our device has the potential to allow for efficient fixation because its negative Poisson's ratio offers micro-movement, thereby causing fixation with relative stability rather than absolute stability. The Auxetic bone plate can be superior to contemporary plate fixation systems, as it demands meaningfully small contact points. The suitable mechanical properties might lessen stress shielding effects that are normally caused by rigid bone plates. The Auxetic nature of the bone will help align and sustain the bone fragments with small fracture gaps in order to impart appropriate assembly to accomplish bone healing. Show more
Keywords: Bone plate, internal fixation, bone fracture, rigid fixation, auxetic, polymeric
DOI: 10.3233/THC-151021
Citation: Technology and Health Care, vol. 23, no. 6, pp. 819-833, 2015
Authors: Terada, Tasuku | Sexsmith, James R.
Article Type: Research Article
Abstract: BACKGROUND : Quantification of sedentary time still remains a challenge. OBJECTIVES: This study examined: 1) whether a multisensory activity monitor could accurately measure sedentary activities and discriminate them from light intensity activities; and 2) the validity of activity log diary (AL) in estimating sedentary time using the monitor as a criterion measure. METHODS: Thirty healthy individuals performed sedentary and light intensity activities in a laboratory while being equipped with a metabolic measurement cart (MMC) and the multisensory monitor. Subsequently, a subset of 19 participants completed AL while wearing the monitor for three days …under free-living conditions. RESULTS: Metabolic equivalents (METs) measured by the multisensory monitor during sedentary activities were similar to those measured by MMC and were significantly lower than light-intensity activities (p< 0.001). Relative criterion validity of AL assessed by Pearson's correlation coefficient was high (r= 0.68, p< 0.01). Absolute criterion validity examined by Bland-Altman plots showed small mean difference between AL and the monitor (36.9 minutes ⋅ day - 1 ) with its limits of agreement ranging from -103.3 to 177.1 minutes ⋅ day - 1 . CONCLUSION: The multisensory monitor is capable of accurately measuring sedentary activities and distinguishing them from light-intensity activities. Compared to the multisensory monitor, our results showed that AL provides valid estimate of overall sedentary time. Show more
Keywords: Validity, self-report, accelerometer, sedentary behavior
DOI: 10.3233/THC-151027
Citation: Technology and Health Care, vol. 23, no. 6, pp. 835-845, 2015
Authors: Bredow, J. | Katinakis, F. | Schlüter-Brust, K. | Krug, B. | Pfau, D. | Eysel, P. | Dargel, J. | Wegmann, K.
Article Type: Research Article
Abstract: INTRODUCTION: Changes in pelvic position can influence the sagittal alignment of the lumbar spine. The restoration of hip kinematics by hip replacement thus appears to offer the possibility of correcting sagittal alignment. This preliminary retrospective study used EOS imaging to investigate the influence of total hip arthroplasty on pelvic parameters in patients with normal preoperative pelvic parameters. METHODS: Twenty patients with hip osteoarthritis undergoing total hip arthroplasty (THA) between 2011 and 2012 received unilateral THA. To evaluate the preoperative and postoperative changes of the pelvic parameters, we analyzed EOS imaging of the patients to determine …pelvic incidence, sacral slope, sacral tilt, pelvic tilt, anterior pelvic plane inclination and pelvic axial rotation. Additionally, anteversion and inclination of the acetabular cup position were determined. RESULTS: No statistically significant difference was found between the preoperative and postoperative measurements of pelvic parameters, although the change in pelvic tilt approached significance. Postoperatively, respective average values of 42.6° and 22.7° were measured for inclination and anteversion of the acetabular cup position. CONCLUSION: THA did not influence pelvic position and sagittal alignment in patients with normal preoperative pelvic parameters. A subsequent study will investigate whether corrections of pelvic parameters outside the norm in patients with OA are possible with THA. Show more
Keywords: Sagittal alignment, total hip arthroplasty, lumbar spine, pelvic parameters, hip osteoarthritis
DOI: 10.3233/THC-151029
Citation: Technology and Health Care, vol. 23, no. 6, pp. 847-854, 2015
Authors: Königshausen, M. | Jettkant, B. | Sverdlova, N. | Ehlert, C. | Gessmann, J. | Schildhauer, T.A. | Seybold, D.
Article Type: Research Article
Abstract: BACKGROUND: There is no biomechanical basis to determine the influence of different length of the central peg of the baseplate anchored within the native scapula in glenoid defect reconstruction in cases of degenerative or posttraumatic glenoid bone loss in reversed shoulder arthroplasty. OBJECTIVE: The purpose of this study was to analyse the stability of different peg lengths used in glenoid bone loss in reversed shoulder arthroplasty. METHODS: Different lengths of metaglene pegs with different depths of peg anchorage performed with or without metaglene screws in sawbone foam blocks were loaded in vertical …and horizontal directions for differentiating load capacities. Simulated physiological loadings were then applied to the peg implants to determine the limits of loading in each depth of anchorage. RESULTS: The loading capacity of the implant was reduced as less of the peg was anchored. The vertically loaded implants showed a significantly higher stability, in contrast to those loaded horizontally at a corresponding peg length and depth of anchorage (p< 0.05). The tests revealed that the metaglene screws are more essential for primary stability than is the peg particularly in the vertically directed loadings (2/3 anchored: peg contributed to 28% of the stability, 1/3 anchorage: peg contributed to 12%). Under the second test conditions, the lowest depth of peg anchorage (1/3) resulted in 322 Newtons [N] in the long peg with a vertical loading direction, and in 130 N in the long peg with a horizontal loading direction (p< 0.05). CONCLUSION: The pegs should be anchored as deeply as possible into the native scapula bone stock. The metaglene screws play a major role in the initial stability, in contrast to the peg, and they become more important when the depth of the peg anchorage is reduced. If possible, four metaglene screws should be used in cases of uncontained bone loss to guarantee the highest stability. Show more
Keywords: Glenoid bone loss, glenoid defect, reversed shoulder arthroplasty, total shoulder arthroplasty, glenoid bone grafting, peg length, omarthrosis, primary stability
DOI: 10.3233/THC-151031
Citation: Technology and Health Care, vol. 23, no. 6, pp. 855-869, 2015
Authors: Beyer, F. | Geier, F. | Bredow, J. | Oppermann, J. | Eysel, P. | Sobottke, R.
Article Type: Research Article
Abstract: BACKGROUND: Non-operative treatment is widely accepted for early stages of lumbar spinal stenosis. In general, a trial of conservative treatment is recommended prior to surgery. OBJECTIVE: The influence of sagittal alignment on treatment outcomes remains unclear. METHODS: Twenty-five patients were included in this prospective study. All patients received repeated epidural injections and facet joint injections as well as physiotherapy during a one week hospitalization. Patient characteristics, VAS scores, COMI scores, ODI scores and SF-36 were assessed prior to and immediately after treatment as well as after six, twelve, and 26 weeks. …Spinopelvic parameter measurements were performed. Outcome parameters were correlated to spinopelvic parameters. RESULTS: ODI and PCSS scores improved significantly up to three months follow-up. COMI score improved significantly over the entire follow-up. Back pain improvement at six weeks and three months follow-up correlated inversely with pelvic incidence. Sacral slope correlated significantly with ODI improvement immediately after therapy. Low lumbar lordosis also correlated significantly with ODI improvement at three months follow-up. CONCLUSIONS: Subjects with higher pelvic incidence reported significantly greater back pain improvements at three months follow-up. ODI improvements were higher for patients with high sacral slope immediately after treatment and for patients with a higher lumbar lordosis after three months. No influence of sagittal alignment was observed on leg pain or quality of life. Show more
Keywords: Lumbar spinal stenosis, non-operative treatment, epidural injections, spinopelvic parameters, sagittal balance
DOI: 10.3233/THC-151032
Citation: Technology and Health Care, vol. 23, no. 6, pp. 871-879, 2015
Authors: Goulet, Eric D.B. | Asselin, Audrey
Article Type: Research Article
Abstract: BACKGROUND: The 24-h urine collection technique is the reference method for assessing sodium intake. Frequent assessments of urinary sodium excretion improve patients' motivation in adhering to sodium-restricted diets. No portable, inexpensive, user-friendly and reliable sodium analyzers are available on the market. Allowing field practitioners access to such an instrument could facilitate patients' monitoring of urinary sodium output, potentially improving patients care and overall population health. OBJECTIVE: To determine the validity and intra- and inter-instruments reliability of two portable, easy-to-use and inexpensive sodium analyzers. METHODS: Urine samples (N= 77) were collected from 31 …men and compared against reference values of an ion chromatograph. RESULTS: Both analyzers demonstrated excellent absolute (95% limits of agreement (LoA) of ± 3-4%) and relative intra-instrument reliability (intraclass correlation coefficients (ICC) of 1.00). Inter-instruments relative reliability was excellent (ICC: 0.99), whereas absolute reliability was good (95% LoA of ± 13%). Compared with results obtained by ion chromatography, relative validity was excellent for both analyzers. Absolute validity was good-to-moderate (95% LoAs ranging from ± 15% to ± 20%). CONCLUSIONS: A low cost, portable analyzer can reliably be used by field practitioners to monitor changes in urinary sodium excretion across time and provide adequate guidance for individuals on sodium-restricted diets. Show more
Keywords: Diet, hypertension, salt, sodium meter, urinary sodium
DOI: 10.3233/THC-151028
Citation: Technology and Health Care, vol. 23, no. 6, pp. 881-891, 2015
Article Type: Other
Citation: Technology and Health Care, vol. 23, no. 6, pp. 893-914, 2015
Article Type: Other
Citation: Technology and Health Care, vol. 23, no. 6, pp. 915-922, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl