Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Purchase individual online access for 1 year to this journal.
Price: EUR 185.00Authors: Jung, E.M. | Stroszczynski, C. | Jung, F.
Article Type: Research Article
Abstract: Goal of the study was the assessment of AI-assisted diagnosis of solid thyroid foci with multimodal modern ultrasound imaging. 50 patients (26–81 years, 54.7±13.1 years) were included in the study. Multimodal ultrasound imaging by means of B-mode with linear probe (4–12 MHz) with option of automated documentation of findings by means of AI, with supplementary Ultra MicroAngiography (UMA) was used. Macrovascularisation was assessed by dynamic contrast ultrasonography (CEUS) with parametric evaluation and perfusion analysis, and microvascularization was assessed by combined strain and shear wave elastography on a novel high-performance ultrasound system (Resona R9/Mindray) by an experienced examiner with independent reading. The …evaluation was performed according to TI-RADS III-V. The volume of the thyroid lobes on both sides averaged 39 ml±5 ml (27 to 69 ml). The 13 cases of histologically confirmed thyroid carcinomas (8 papillary, 2 medullary, 2 microfollicular, 1 anaplastic CA) with a mean size of 15 mm±6 mm (9–21 mm) were correctly evaluated by TI-RADS V on the basis of irregular shape, induration > 2.5 m/s or > 30kPA and striking wash-out kinetics. Tumor lymph nodes could only be correctly detected preoperatively in one case of medullary carcinoma according to the surgical findings, based on irregular vascularization with UMA in roundish shape with cortex > 4 mm, transverse diameter up to 11 mm. In 25 cases of inhomogeneous nodular goiter an evaluation with TI-RADS III was performed in 31 cases, in 4 cases with incomplete marginal contour, partial marginal vascularization with UMA and partial wash out with indurations up to 2.5 m/s 30 kPA an evaluation with TI-RADS IV and surgical excision for nodular goiter. In 12 cases regressive nodular changes without relevant malignancy criteria resulted in nodular goiter, with focal changes up to 1.5 cm in diameter, classified as requiring control with TI-RADS III. There were no relevant changes in findings in the controls after 6 months. From the AI tool, the 20/25 goiter nodes were assessed as TI-RADS III, 7/12 adenomas, 5 goiter nodes, and 5 adenomas as TI-RADS IV, 5/13 carcinomas as TI-RADS IV, and 8/13 carcinomas as TI-RADS V. Multimodal ultrasound diagnostics supported by AI has a high diagnostic potential for the evaluation of solid thyroid lesions and standardizes the reporting with digital representative image documentation. CEUS perfusion and modern elastography techniques allow targeted follow-up of TI-RADS III findings. Show more
Keywords: Thyroid lesions, multimodal ultrasound, artificial intelligence (AI), UMA-elastography, contrast enhanced ultrasonography (CEUS), parametric-perfusion analysis
DOI: 10.3233/CH-239102
Citation: Clinical Hemorheology and Microcirculation, vol. 84, no. 2, pp. 227-236, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl