Price: EUR 185.00Authors: Witte, Siegfried | Copley, Alfred L.
Article Type: Other
DOI: 10.3233/CH-1991-11601
Citation: Clinical Hemorheology and Microcirculation, vol. 11, no. 6, pp. 569-570, 1991
Authors: Copley, Alfred Lewin
Article Type: Other
DOI: 10.3233/CH-1991-11602
Citation: Clinical Hemorheology and Microcirculation, vol. 11, no. 6, pp. 571-573, 1991
Authors: Ernst, E. | Botzenhardt, R. | Matrai, A. | Weimer, B. | von Arnim, T.
Article Type: Research Article
Abstract: Plasma viscosity and the viscous component of blood viscosity were measured in an oscillatory capillary viscometer (OCR-D) and compared to the blood viscosity determined in the Contraves LS-30 machine at identical nominal shear rates and to plasma viscosity readings obtained in the Coulter Harkness capillary viscometer. The OCR-D system yields lower reproducibility compared to the other methods. It also gives lower absolute viscosity readings for blood at low shear rates. Hemoconcentration, as induced in vivo by a standard ergometer exercise, is less strongly reflected in the low shear blood viscosity data from the OCR-D system compared to the analogue results …obtained in the LS-30. These findings suggest, that the OCR-D method is less reproducible and not directly comparable with the “conventional” methods. Possibly the latter are best for routine while oscillatory methods may give a more detailed analysis of specific questions. Show more
Keywords: viscometry, oscillary capillary viscometer, rotational viscometer, methodological comparison
DOI: 10.3233/CH-1991-11603
Citation: Clinical Hemorheology and Microcirculation, vol. 11, no. 6, pp. 575-581, 1991
Authors: Bruneau, C. | Laustriat, D. | Camberlein, V. | Cremel, G. | North, M.L.
Article Type: Research Article
Abstract: The purpose of this investigation was to correlate, on intact red blood cells (RBC) , deformability and membrane fluidity. RBC deformability was measured by their filterability through a 4.8 um diameter pore filter and membrane fluidity was tested with trimethylammonium-diphenylhexatriene (TMA-DPR), a specific plasma membrane fluorescent probe. RBC were untreated or experimentaly modified according to Shinitzky's method with 25-OH-cholesterol (25OH-chol) and with cholesterol-hemisuccinate (CHS). These cholesterol analogs are known as rigidifying agents of the membranes. Whereas 25OH-chol treatment did not induce any change of fluidity and filterability on intact RBC, CHS treatment provoked most modifications on intact RBC: it induced …a membrane fluidization (as compared to control cells) and a spherocytosis with a 5.5% increase of the mean corpuscular volume (MCV), without any alteration of filterability measurements. Concurrently fluorescence polarization measurements on ghosts obtained from CHS treated cells, which retain hemoglobin, did not show significative fluidity modification whereas 25OH-chol treatment decreased it. We conclude that there is no direct correlation between erythrocyte deformability as measured by filterability and membrane fluidity on entire cells. It appears to be of a great importance to test fluidity on ghosts and on intact cells. Different membrane localisation of the two cholesterol derivatives tested may explain their different impact on membrane. Show more
Keywords: erythrocyte deformability, membrane fluidity, TMA-DPH, intact erythrocytes, cholesterol hemisuccinate
DOI: 10.3233/CH-1991-11604
Citation: Clinical Hemorheology and Microcirculation, vol. 11, no. 6, pp. 583-595, 1991
Authors: Le Devehat, C. | Khodabandehlou, T.
Article Type: Research Article
Abstract: Troxerutine is shown to be of clinical interest in some pathological circumstances particularly in venous insufficiency. One particularly interesting effect of Troxerutine is its hemorheological action. Indeed. it is shown to inhibit the red blood cell hyperaggregation in vitro and in vivo. The aim of the present work is to appreciate the effect of Troxerutine on red blood cell aggregation in diabetic angiopathy. Aggregation measurements were performed with Sefam and Myrenne aggregometers. Moreover, hemodynamic and transcutaneous oxygen pressure measurements were performed. These measurements might help to better understand the clinical effects of Troxerutine.
Keywords: Hemorheology, diabetic angiopathy, Troxerutine, microcirculation
DOI: 10.3233/CH-1991-11605
Citation: Clinical Hemorheology and Microcirculation, vol. 11, no. 6, pp. 597-603, 1991
Authors: Gelmini, G. | Quaini, F. | Mineo, F. | Moccia, G. | Ricci, R. | Lagrasta, C. | Delsignore, R. | Olivetti, G.
Article Type: Research Article
Abstract: Uncorrected and corrected blood viscosity, plasma viscosity and whole blood filterability were evaluated in 15 rats submitted to an iron-copper (Fe-Cu) free diet and 15 rats fed with the same diet supplemented with the daily requirement of the two minerals. Hemathological parameters (Hb, MCV, PCV, MCH, white, red blood cell and platelet total counts) were also measured. Fe-Cu deficient rats developed severe microcytic anemia within 7–8 weeks of diet. This was associated with a 43% and 31% decrease of blood viscosity and whole blood filterability, respectively. Higher values of corrected blood viscosity and white cell total counts were found in …anemic respect to control rats fed with Fe-Cu supplemented diet. Results of plasma viscosity were similar in both groups. Our study shows that severe sideropenic anemia is accompanied by hemorheological alterations leading to a significant reduction of whole blood filterability. It is suggested that, in microcytic anemia, microcirculatory flux is impaired and this phenomenon may play an important role in anemia-induced tissue hypoxia. Show more
Keywords: anemia, iron deficiency, hemorheology, blood viscosity, whole blood filterability
DOI: 10.3233/CH-1991-11606
Citation: Clinical Hemorheology and Microcirculation, vol. 11, no. 6, pp. 605-615, 1991
Authors: Caimi, Gregorio | Lo Presti, Rosalia | Serra, Antonio | Grifo, Giacomo | Sarno, Antonio
Article Type: Research Article
Abstract: In a group of 21 subjects with vascular atherosclerotic disease (VAD) we evaluated the cytosolic red cell Ca2+ content (employing Fura-2AM), the total red cell Ca2+ content (using an atomic absorption spectrophotometer) and the erythrocyte membrane fluidity (marking intact red blood cells with pyrene). From the obtained results, it is evident that cytosolic and total red cell Ca2+ content do not distinguish normals from VAD subjects. Erythrocyte membrane fluidity discriminates normals from VAD subjects. No relationship is present between erythrocyte membrane fluidity, total and cytosolic red cell Ca2+ content.
Keywords: Cytosolic red cell Ca2+ content, Total red cell Ca2+ content, Erythrocyte membrane fluidity, Vascular atherosclerotic disease
DOI: 10.3233/CH-1991-11607
Citation: Clinical Hemorheology and Microcirculation, vol. 11, no. 6, pp. 617-621, 1991
Authors: Bertram, B. | Hoberg, A. | Arend, O. | Wolf, S. | Jung, F. | Kiesewetter, H. | Reim, M.
Article Type: Research Article
Abstract: Rheological parameters (hematocrit, plasma viscosity, red blood cell aggregation and red blood cell rigidity) and the plasma proteins fibrinogen, alpha-2-macroglobulin and immunglobulin M were measured in 70 patients with acute anterior ischemic optic neuropathy (AION). In all patients AION was diagnosed by acute decrease of central visual acuity and visual field, typical ophthalmoscopic and angiographic fundus changes and exclusion of other causes of papilledema. The mean values of hematocrit (men 46 ± 4% ,women 43 ± 5%), RBC aggregation (14,0 ± 5,0, normals: 14,6 ± 3,2) and RBC rigidity (0,99 ± 0,07, normals: 1,01 ± 0,09) were equal to …normals. Plasma viscosity (1,40 ± 0,14 mPas, normals: 1,24 ± 0,05 mPas) was increased. A significant correlation was found between plasma viscosity and the plasmaproteins fibrinogen (0,55) and (in women) Immunglobulin M (0,46). Patients with AION and giant cell arteritis showed higher plasma viscosity than patients with AION and no giant cell arteritis. In patients with non-arteritic AION the presence or absence of hypertension or diabetes mellitus seems not to influence the blood rheology. The altered plasma viscosity in AION may be one of the reasons for disturbed microcirculation in AION. Show more
Keywords: Blood rheology, hematocrit, plasma viscosity, red blood cell aggregation, fibrinogen, anterior ischemic optic neuropathy
DOI: 10.3233/CH-1991-11608
Citation: Clinical Hemorheology and Microcirculation, vol. 11, no. 6, pp. 623-634, 1991
Authors: Chen, Huai-Qing | Zhou, Dong | Li, Liang | Zhong, Gui-Hui | Yuan, Guang-Gu
Article Type: Research Article
Abstract: Few of paper on alteration in thixotropic properties of blood from patients with cerebral vascular diseases has been found yet. With Low Shear 30 rheometer, we modified the measuring protocol according to Huang's equation and determined the thixotropic parameters of whole blood from 72 male patients with cerebral vascular diseases, thus we compared these parameters with those of blood from healthy subjects matched in sex and age. The results demonstrated that the yield stress, non-Newtonian contribution of viscosity, apparent viscosity (2.37 s−1 ) and the equilibrium value of structure parameters in the patients with cerebral arteriosclerosis (CA, n=14), transient cerebral …ischemic attack (TIA, n=12) and cerebral thrombosis (n=46) were significantly higher than those of corresponding control groups. However, there were no significant changes in hematocrit, Newtonian contribution of viscosity and apparent kinetic rate constant of rouleaux breakdown. No significant differences of the thixotropic parameters existed among groups of CA, TIA and cerebral thrombosis. The results suggest that the patients with cerebral vascular diseases had evidently increased the amount and degree of RBC aggregation. Further more, before onset of cerebral thrombosis the patients with CA and TIA had already obvious change in thixotropy of blood. This probably implies that abnormality of thixotropy of blood is not a trigger factor for ischemic stroke, but a possible subsidiary or an associated risk factors. Show more
Keywords: Hemorheology, thixotropy of blood, RBC aggregation, hematocrit, ischemic stroke
DOI: 10.3233/CH-1991-11609
Citation: Clinical Hemorheology and Microcirculation, vol. 11, no. 6, pp. 635-640, 1991
Authors: Giansanti, R. | Boemi, M. | Badiali, M. | Fumelli, P.
Article Type: Research Article
Abstract: Obesity as well as diabetes is associated with modifications of normal blood flow properties. Erythrocyte aggregation, expressed as mean entity of aggregation or MEA, was determined in a group of 83 obese type II diabetic patients and in a group of 148 obese non diabetic subjects. Furthermore 148 non obese and non diabetic individuals were studied as controls. Obese subjects, with and without diabetes, showed significantly higher values of erythrocyte aggregability as compared to controls. Erythrocyte aggregation tended to increase according to the degree of obesity among non diabetic subjects. The rheological abnormality was more …evident among diabetic patients: the highest MEA values were recorded in this group but a correlation with the body mass index was lacking. Show more
Keywords: blood rheology, erythrocyte aggregation, obesity
DOI: 10.3233/CH-1991-11610
Citation: Clinical Hemorheology and Microcirculation, vol. 11, no. 6, pp. 641-647, 1991
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl