Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Purchase individual online access for 1 year to this journal.
Price: EUR 185.00Authors: Wiggermann, P. | Zeman, F. | Nießen, C. | Agha, A. | Trabold, B. | Stroszczynski, C. | Jung, E.M.
Article Type: Research Article
Abstract: Purpose: The aim of this study is to describe the image findings of contrast-enhanced ultrasound (CEUS) after irreversible electroporation (IRE), and to assess its usefulness in relation to the evaluation of the ablation status using a dynamic recording of the microvascularisation. Material and method: In this prospectively designed study, a percutaneous IRE was performed for the treatment of malignant hepatic lesions in a total of 15 patients following the interdisciplinary diagnosis. The lesions were documented using CEUS before, immediately after and 20 minutes after the ablation. The acquired CEUS image data was subsequently independently retrospectively evaluated by 2 experienced radiologists …and assessed in relation to microvascularisation using a 5 point scale. Results: Using CEUS, a significant reduction in the microcirculation of the lesions, both centrally and marginally, could be detected following IRE (p < 0.001 and p < 0.001). The mean evaluation of the central microcirculation was reduced from 3.13 ± 1.38 to 0.47 ± 0.64 (p < 0.01). For the peripheral area of the lesion and the ablation margin, there was a reduction of 3.37 ± 1.13 to 1.57 ± 0.46 (p = 0.001). There was no significant reduction in the macrocirculation. Conclusion: Within the framework of this study, it could be demonstrated that, in the course of IRE, a rapid significant reduction of the microcirculation in the ablation area occurred. Show more
DOI: 10.3233/CH-2012-1615
Citation: Clinical Hemorheology and Microcirculation, vol. 52, no. 2-4, pp. 417-427, 2012
Article Type: Other
Citation: Clinical Hemorheology and Microcirculation, vol. 52, no. 2-4, pp. 429-435, 2012
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl