Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Purchase individual online access for 1 year to this journal.
Price: EUR 185.00Authors: Rampling, M. W. | Brown, J. R. | Robinson, R. J. | Feher, M. D. | Cholerton, S. | Sever, P. S.
Article Type: Research Article
Abstract: Rheological measurements were made on the blood of 22 chronic cigarette smokers (8 males, 14 females) 2 weeks before and 2 weeks after complete abstention from smoking. Significant reductions were observed in blood viscosity at both high and low shear rates and in plasma viscosity. These changes could be related to alterations in packed cell volume and plasma fibrinogen concentration, both of which fell significantly over the same period. The male and female groups responded similarly. These data indicate that a significant improvement occurs in rheologically-related cardiovascular risk factors in cigarette smokers within two weeks of abstaining from tobacco.
Keywords: Haemorheology, blood viscosity, smoking, tobacco
DOI: 10.3233/CH-1991-11521
Citation: Clinical Hemorheology and Microcirculation, vol. 11, no. 5, pp. 441-446, 1991
Authors: Bernasconi, C. | Del Santo, A. | Marrali, F. | Laffranchi, M. | Milani, S. | Agostoni, A.
Article Type: Research Article
Abstract: In order to define normal reference limits of a power law fitting method for evaluating whole blood viscosity, 110 healthy subjects were studied. We found that whole blood viscosity and blood viscosity standardized for hematocrit and plasma viscosity influence were significantly different in adult males, adult females and subjects over 60 years old (p<0.0001). In our opinion, it was also possible to distinguish blood viscosity differences into red blood cells aggregability and deformability components.
Keywords: blood viscosity, plasma viscosity, sex, age
DOI: 10.3233/CH-1991-11522
Citation: Clinical Hemorheology and Microcirculation, vol. 11, no. 5, pp. 447-457, 1991
Authors: Zong-Yao, Wen | Zu-Lai, Tao | Shi, Cao | yu-Heng, Zhao | Zhan-Shan, Han | Yu-Mei, Li | Shu-Hua, Lu | Hong-ru, Wang | Jia-Ling, Xu | Gong, Li | Gui-Fen, Yu | Ben-Jie, Wu
Article Type: Research Article
Abstract: In order to find a new suspending medium for Ektacytometric measurement, comparisons of measured rheological properties of erythrocyte suspension in different buffers were carried out. Two kinds of buffer were used, e.g. PBS and PVP. And four types of erythrocyte were measured by using both suspending media, namely: normal rabbit's erythrocytes (RBC), rabbit's RBC hardened by formalin with different concentrations, rabbit's RBC treated by trypsin and human erythrocyte sampled from patients. Microscopic and scanning electron microscopic photographs of erythrocytes rigidizied at constant shear rate were observed. Results showed that (1) for everyone of the these four kinds of erythrocytes, measured …deformation index (D1)—shear rate ($\dot{\gamma}$ ) curves in PBS are similar qualitatively to those measured in PVP. (2) Microscopic and scanning electron microscopic photographs showed that erythrocytes indeed deformed when the shear rate of flow field for PBS was as low as $\dot{\gamma}=20s^{-1}$ . It indicated that PBS could be used as suspending medium. On the contrary when we used PVP ($\dot{\eta}=2$ mPas Fig. 1 [1]) as suspending medium at $\dot{\gamma}=800s^{-1}$ , no obvious deformation could be obtained by using Ektacytometer. It seems to mean that, as the suspending medium for Ektacytometric measurement, PBS would be better than PVP, especially in low shear stress area. This point of view is different from that of privous works [2] which do 1101 consider PBS as suspending medium of Ektacytometer. Show more
Keywords: deformability, Suspending medium, Ektacytometric
DOI: 10.3233/CH-1991-11523
Citation: Clinical Hemorheology and Microcirculation, vol. 11, no. 5, pp. 459-464, 1991
Authors: Roux, Jacques | Dumont, Jean-Maurice | Aellig, Alain | Imamura, Toshiko
Article Type: Research Article
Abstract: The effect of subcutaneous treatment of turpentine on hemorheological parameters was studied ex vivo in rats. A dose-response study (0.2 to 5 ml/kg) was performed on a series of parameters: whole blood apparent viscosity, plasma viscosity, plasma fibrinogen content, total plasma protein, hematocrit, erythrocyte aggregation and filterability. Significant alterations of all hemorheological parameters were observed 24 hrs after the turpentine treatment except for erythrocyte filterability and hematocrit values. In most cases, these alterations were significant (p<0.01) for doses higher than 0.3 ml/kg, with a maximum effect usually observed for a dose ≥ 1 ml/kg. These hemorheological alterations were still present …48 hrs after turpentine treatment and in the same order of magnitude. Thus, the present study demonstrated for the first time that turpentine treatment induced significant alterations of hemorheological parameters in dose-dependent manner, probably via an increase in plasma protein components. Show more
Keywords: Turpentine oil, inflammation, hemorheology, animal model
DOI: 10.3233/CH-1991-11524
Citation: Clinical Hemorheology and Microcirculation, vol. 11, no. 5, pp. 465-477, 1991
Authors: Scheffler, A. | Steinbach, U. | Rieger, H.
Article Type: Research Article
Abstract: Whether erythrocyte deformability is reduced in patients with peripheral occlusive arterial disease (POAD) is discussed controversially. Within this study erythrocyte filterability through microfilters with different pore diameters (3, 5, and 8 μm) was investigated in patients with POAD and age-matched healthy volunteers under physiological and ischaemia-related boundary conditions (lactate acidosis, hypercapnia, hypoxia, hyperosmolarity). 70 subjects were assigned to two control and three POAD groups characterized by varying combinations of risk factors (smoking, diabetes mellitus). Red blood cells (RBC) were suspended in four different media (pH/ mosmol *l−1 : 7.4/ 300, 7.4/400, 6.5/300, 6.5/400) containing a physiological bicarbonate buffer adequately …gased with O2 /CO2 /N2 . Mean hematocrit-corrected relative erythrocyte transit times (RCTT) and concentrations of clogging particles (CP) were measured by means of the St. George's Filtrometer. In agreement with previous reports, filtration data varied with erythrocyte volume (MCV) and mean corpuscular hemoglobin concentration (MCHC) used as estimates of surface area-to-volume ratio (SAVR) and inner viscosity (IV) of RBC, respectively. While RBC filtration rates were dominated by IV in 5 and 8 μm pores they were mainly limited by SAVR in 3 μm pores. For RCTT statistically significant differences between controls and POAD patients could not be found. CP correlated with leucocyte counts of the suspensions if filterability was not primarily limited by MCV. A quantitative agreement among these parameters, however, was only obtained in 8 μm pores and, therefore, interactions between both erythrocytes themselves and erythrocytes and leucocytes should have contributed to filter obstruction. For CP statistically significant differences were only found between controls and diabetic POAD patients in whom also higher leucocyte counts were registered. It is concluded that in clinical or pharmacological studies of RBC filterability the most important in-vitro boundary conditions (milieu, filter pore size) should be varied in order to account for the complex and partially antagonistical relationships between erythrocyte properties and pore geometry as well as blood cell interactions. Because the capillary morphology of ischaemic tissue areas is usually not known or may be subjected to dynamic alterations the meaning of the invitro filterability with respect to the in-vivo microcirculation is additionally insecured. Show more
Keywords: Erythrocyte Filterability, Peripheral Vascular Disease, Ischaemia, Pore Size, Microcirculation
DOI: 10.3233/CH-1991-11525
Citation: Clinical Hemorheology and Microcirculation, vol. 11, no. 5, pp. 479-495, 1991
Authors: Dikmenoğlu, N. | Başkurt, O.K. | Levi, E. | Çağlayan, S. | Güler, S.
Article Type: Research Article
Keywords: Sulfur dioxide, erythrocyte deformability, lipid peroxidation
DOI: 10.3233/CH-1991-11526
Citation: Clinical Hemorheology and Microcirculation, vol. 11, no. 5, pp. 497-499, 1991
Authors: Keeling, D. | Isenberg, D. | Patterson, K.
Article Type: Research Article
Keywords: Plasma viscosity, erythrocyte sedimentation rate, systemic lupus erythematosus
DOI: 10.3233/CH-1991-11527
Citation: Clinical Hemorheology and Microcirculation, vol. 11, no. 5, pp. 501-506, 1991
Authors: Zong-Yao, Wen | Shi, Cao | Zu-Lai, Tao | Yu-Heng, Zhao | Yu-Mei, Li | Shu-Hua, Lu | hong-Rut, Wang | Jia-Ling, Xu | Gong, Li | Gui-Fen, Yu | Ben-lie, Wu
Article Type: Research Article
Keywords: Osmostic presure, deformability, Ektacytometric osmoscan curve
DOI: 10.3233/CH-1991-11528
Citation: Clinical Hemorheology and Microcirculation, vol. 11, no. 5, pp. 507-510, 1991
Article Type: Other
DOI: 10.3233/CH-1991-11529
Citation: Clinical Hemorheology and Microcirculation, vol. 11, no. 5, pp. 511-512, 1991
Article Type: Abstract
DOI: 10.3233/CH-1991-11530
Citation: Clinical Hemorheology and Microcirculation, vol. 11, no. 5, pp. 513-521, 1991
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl