Abstract: Seven females, six laboratory assistants, participated in the experimental part of the study. The level of muscular activity in different sitting work postures was recorded, using surface electrodes, as full-wave-rectified and low-pass filtered EMG, and normalised. The laboratory assistants also rated the degree of exertion in four different body regions during their ordinary microtome sectioning work, comparing the use of anterior chest support with the use of their usual chair with lumbar support. The use of anterior chest support reduced the muscular activity in the lumbar back muscles but increased it in the shoulder muscles. Perceived exertion in the neck, shoulders and thoracic back regions increased. Anterior chest support does not seem to solve the problem of neck- and-shoulder load-elicited pain during the work of preparing laboratory sections.
Keywords: Anterior chest support, Cervical spine, Chair, EMG, Ergonomics, Lumbar support, Female, Muscle function, Neck/shoulder and back muscles, Sitting posture, Work posture
DOI: 10.3233/WOR-1996-6202
Journal: Work, vol. 6, no. 2, pp. 77-85, 1996
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl