Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Larson, Robert E.a; 1; * | Murtagh, Elise M.b; 1 | Rice, Martin S.c
Affiliations: [a] Department of Exercise Science, Brigham Young University, Provo, UT, USA | [b] Western Reserve Hospital, Cuyahoga Falls, OH, USA | [c] School of Health Sciences, Indiana Wesleyan University, Marion, IN, USA
Correspondence: [*] Address for correspondence: Robert E. Larson, OTD, OTR/L, Department of Exercise Science, Brigham Young University, 106 Smith Fieldhouse, Provo, UT 84663, USA. Tel.: +1 360 442 1304; Fax: +1 801 422 0555; E-mail: robert.eugene.larson@gmail.com.
Note: [1] This work was completed as partial fulfillment for the Occupational Therapy Doctoral Degree at the University of Toledo for the first two authors.
Abstract: BACKGROUND:This study investigated the effects of 3 different types of slide sheets upon hand forces while sliding a patient up in bed. METHODS:The sheets used included the reusable Arjo Maxislide, the McAuley disposable sheet, and a standard cotton sheet. Hand forces were measured from 38 male and female participants as they slid a ‘patient’ up in bed. A repeated measures ANOVA with 5 levels to the repeated factor (number of sheets and sheet type) was used, along with post-hoc repeated measures contrasts to compare differences between each condition. RESULTS:A significant reduction in required force occurred when using the friction reducing sheets as compared to the cotton sheets when used according to manufacturer recommendations, as well as a reduction in one of the single friction reducing sheet categories compared to the cotton. However, it is important to note that there was still substantial force being placed on the participants. CONCLUSIONS:This study illustrates the importance of using friction reducing slide sheets while engaging in manual patient handling. Future research should investigate the forces involved with other friction reducing materials and methods as well as the possibility of combining said materials and methods.
Keywords: Friction, nursing staff, hospital, body mechanics, sheets
DOI: 10.3233/WOR-182688
Journal: Work, vol. 59, no. 3, pp. 439-448, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl