Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Shariat, Ardalana; * | Tamrin, Shamsul Bahri Mohda | Arumugam, Manoharb | Danaee, Mahmoudc | Ramasamy, Rajeshd
Affiliations: [a] Department of Occupational Health, Faculty of Medicine and Health Sciences, University Putra Malaysia, Malaysia | [b] Department of Orthopedics, Faculty of Medicine and Health Sciences, University Putra Malaysia, Malaysia | [c] University of Malaya Centre of Addiction Sciences (Umcas), Malaysia | [d] Department of Pathology, Faculty of Medicine and Health Sciences, University Putra Malaysia, Malaysia
Correspondence: [*] Address for correspondence: Ardalan Shariat, Department of Occupational Safety and Health, Faculty of Medicine and Health Sciences, University Putra Malaysia, Serdang, Selangor, Malaysia. Tel./Fax: +60 389583134; HP: +60 173365494. E-mail: ardalansh2002@gmail.com.
Abstract: BACKGROUND: The accuracy of instruments such as questionnaires and the goniometer are critical for measuring the severity of musculoskeletal disorders among office workers. OBJECTIVE: To determine the reliability of the Cornell questionnaire, goniometer and Borg questionnaire, which are commonly used instruments to assess the severity of musculoskeletal disorders in office workers. METHODS: One hundred twenty healthy office workers, body mass: 87.1 ± 10.3 (kg), age: 27 ± 5.1 (years), height: 1.78 ± 0.16 (m), (mean ± SD), who had at least 1 year of experience in office working, were chosen randomly. A plastic goniometer (30" height) was used three times to measure the range of motion in the neck, hip, knee and shoulder area, with a period of one hour between measurements to evaluate the test-retest accuracy. The Cornell questionnaire was used to measure the severity of musculoskeletal disorders and the Borg scale was used to measure perceived exertion. The questionnaires were filled out twice with a gap of 2 weeks between measurements. RESULTS: The Inter-class Correlation Co-efficient (ICC) indicated that all instrument sub-scales showed high levels of repeatability. The ICC coefficient was (0.805–0.954, p <0.001) for the Borg scale, (0.785–0.978, p <0.001) for the goniometer and (0.883–0.975, p <0.001) for the Cornell questionnaire. CONCLUSIONS: The Cornell questionnaire, goniometer and Borg questionnaire all exhibit high reliability when used for the evaluation of the severity of musculoskeletal disorders in office workers.
Keywords: Cornell questionnaire, reliability, goniometer, Borg questionnaire
DOI: 10.3233/WOR-162313
Journal: Work, vol. 54, no. 3, pp. 753-758, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl