Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Coelho, Denis A.a; * | Lourenço, Miguel L.b; c
Affiliations: [a] Department of Supply Chain and Operations Management, School of Engineering, Jönköping University, Jönköping, Sweden | [b] C-MAST: Centre for Mechanical and Aerospace Science and Technologies, Universidade da Beira Interior, Covilhã, Portugal | [c] Engineering and Technology Technical Scientific Unit & Research Unit for Inland Development, Technology and Management School, Guarda Polytechnic Institute, Guarda, Portugal
Correspondence: [*] Address for correspondence: Denis A. Coelho, Department of Supply Chain and Operations Management, School of Engineering, Jönköping University, 55111 Jönköping, Sweden. Tel.: +46 311 013 51; E-mail: denis.coelho@ju.se.
Abstract: BACKGROUND:Static muscular activity of muscles activated in the use of the conventional PC mouse is believed to represent a higher risk for the musculoskeletal health of the user than dynamic muscular activity. OBJECTIVE:This paper presents a compounded muscular activity dynamics indicator (akin to percent relative range), enabling comparison between computer handheld pointing devices. METHODS:This muscular dynamism approach considers baseline muscular activity (APL, ECR, ECU and ED) relative to the Maximum Voluntary Contraction as well as the dynamics of muscular activation. The latter is computed as the ratio of the difference between APDF90 and APDF10 divided by APDF50 (APDF-Amplitude Probability Distribution Function for the 90th, 50th and 10th percentiles). The paper demonstrates the approach with results of comparative evaluation of a horizontal, a slanted and a vertical PC mouse, through surface EMG monitoring of 20 participants performing standardized graphical task with the devices. RESULTS:Hand size impacts muscular activity dynamics in these four muscles, which supersedes differences in device geometry, across the range of devices tested. CONCLUSION:Smaller devices relative to hand size foster more dynamic muscular activity.
Keywords: Graphical tasks, static contractions, hand size, conventional mouse, percent relative range, APL, ECR, ECU, ED, APDF, MVC, S-EMG, dynamic muscular activity
DOI: 10.3233/WOR-203242
Journal: Work, vol. 68, no. 1, pp. 123-135, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl