Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Caron, Alexis | Hacquard, Marie | Audibert, Gérard | Cauchois, Ghislaine | Vigneron, Claude | Stoltz, Jean-François | Longrois, Dan | Menu, Patrick; ;
Affiliations: Laboratory of Hematology and Physiology, EA 3452, Faculty of Pharmacy, University Henri Poincaré, Nancy, France | Departments of Anesthesia and Intensive Care and EA 3447, CHU Nancy, France | Laboratory of Mechanical and Engineer of Cell and Tissue, UMR- CNRS- INPL-UHP 7563, IFR 111, Faculty of Medicine, Vandoeuvre les Nancy, France
Note: [] Corresponding author: Dr. Patrick Menu, Laboratoire d'Hématologie et de Physiologie, Faculté de Pharmacie, 5 rue Albert Lebrun, 54001 Nancy cedex, France. Tel.: +33 383 682 321; Fax: +33 383 682 319; E-mail: menu@pharma.uhp-nancy.fr.
Abstract: Objectives: It has been shown that a hydroxyethylstarch solution significantly increases the aortic distensibility coefficient (ADC) as compared to other non-hydroxyethylstarch colloid solutions. In order to investigate whether the effect of hydroxyethylstarch on ADC is class-specific, we investigated the effect of two hydroxyethylstarch solutions (HES 200: Elohes® and HES 240: Hesteril®) on the ADC and compared them with two other colloid solutions: 5% albumin and fluid gelatin (Gelofusin®) in a rabbit model of acute isovolumic hemodilution. Methods: Twenty-eight male New Zealand white rabbits were anesthetized and randomly allocated to receive (n=7, each): albumin, hydroxyethylstarch-200, hydroxyethylstarch-240 and gelatin for acute isovolumic hemodilution by exchanging 13 ml.kg−1 body weight of blood with an identical volume of the test solution. Blood viscosity, mean arterial pressure, aortic blood flow and heart rate were measured and ADC was calculated. Results: All groups were comparable with respect to arterial pressure, heart rate and aortic blood flow velocity before and after isovolumic hemodilution. After hemodilution, ADC coefficient remained unchanged as compared with pre-hemodilution values with albumin, hydroxyethylstarch-240 and gelatin, whereas a sustained 3 fold increase was observed with hydroxyethylstarch-200. Conclusion: These results demonstrate that minor physicochemical differences between two hydroxyethylstarch solutions result in measurable differences in ADC and suggest that the clinical effects of colloids should probably be analyzed for each type of colloid and not for classes of colloids (e.g. hydroxyethylstarch or fluid gelatins).
Keywords: Hydroxyethylstarch 240, aortic distensibility coefficient, acute isovolumic hemodilution, colloids
Journal: Clinical Hemorheology and Microcirculation, vol. 35, no. 4, pp. 447-458, 2006
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl