Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Ruef, P. | Pöschl, J.M.B. | Linderkamp, O.
Affiliations: Division of Neonatology, Department of Pediatrics, University of Heidelberg, Im Neuenheimer Feld 153, D‐69120 Heidelberg, Germany
Note: [] Corresponding author: Dr. P. Ruef, Division of Neonatology, Department of Pediatrics, University of Heidelberg, Im Neuenheimer Feld 153, D‐69120 Heidelberg, Germany. Tel.: 0049 6221 562308; Fax: 0049 6221 565602; E‐mail: peter_ruef@med.uni‐heidelberg.de.
Abstract: The red blood ceIl (RBC) membrane forms tethers in response to shear forces acting on tiny membrane points. Tether formation depends on viscous and elastic membrane properties and has been used as indicator of membrane fragility. A micropipette technique was used to study time dependent tether formation and tether relaxation of individual RBC. Point attached RBC were aspirated at a negative pressure of −5 mm H2O into a micropipette with an internal diameter of 7.8 μm. If tether formation occurred and the tether reached a length of approximately 16 μm, the pipette was carefully pulled back. The RBC left the orifice of the micropipette and the tether relaxed and pulled the main body of the RBC back to the attachment point. The relaxation of the tethers was exponential. The time constant for tether relaxation was 0.144 s which is similar to the time constant for recovery of entire RBC from extensional elastic deformation. Repeated tether formation and relaxation of the same RBC led to an earlier begin of tether formation and changed the behavior of tether growth, although the relaxation time did not change. We conclude that repeated tether formation decreases the resistance of the RBC membrane to form tethers upon given shear forces. Weakening of the membrane due to repeated plastic deformation may play a role in the membrane loss of circulating RBC during aging.
Journal: Clinical Hemorheology and Microcirculation, vol. 30, no. 1, pp. 39-46, 2004
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl