Issue title: Selected articles from the 3rd Joint Meeting of The European Society for Clinical Hemorheology and Microcirculation (ESCHM) , The International Society for Clinical Hemorheology (ISCH) and The International Society of Biorheology (ISB), Regensburg, Germany, 28 – 30 September 2023
Guest editors: L. Prantl, A. Krueger-Genge and F. Jung
Article type: Research Article
Authors: Strauss, Catharinaa; * | Fodor, Katharina J.b | Anker, Alexandrab | Kemper, Robertb | Prantl, Lukasb | Brébant, Vanessab | Bosselmann, Taliab | Geis, Sebastianb
Affiliations: [a] Department of Trauma Surgery, Orthopedics, Plastic and Hand Surgery, University of Augsburg, Augsburg, Germany | [b] Department of Plastic, Hand and Reconstructive Surgery, University of Regensburg, Regensburg, Germany
Correspondence: [*] Corresponding author: Catharina Strauss, University of Augsburg, Department of Trauma surgery, Orthopedics, Plastic and Hand Surgery, Stenglinstrasse 2, 86155 Augsburg, Germany. E-mail: catharina_strauss@hotmail.com.
Abstract: BACKGROUND:Monitoring replanted digits remains a challenging task in microsurgical units. Previous studies have indicated the perfusion index (PI), a parameter directly proportional to the blood flow, might be a useful tool. OBJECTIVE:The PI is evaluated as a monitoring tool in patients with replanted digits. METHODS:This prospective, non-interventional study includes 31 patients with revascularized or replanted digits. After successful revascularization or replantation, the PI and peripheral oxygen saturation of the affected finger and its contralateral equivalent were measured simultaneously. The values were detected by the device Radical-97® Pulse CO-Oximeter® (Masimo Corporation, 52 Discovery, Irvine, CA 92618, USA). RESULTS:The median PI of affected fingers was 3.5±0.56 for revascularized and 2.2±0.8 for replanted fingers. The difference between the PI values of replanted digits and the healthy contralateral side was highly significant (p < 0.0001). The area under the curve in the receiver operating characteristics was 0.92 for a PI difference > 80.49% and predicted a loss of replant with a specificity of 100% and a sensitivity of 75%. CONCLUSION:The assessment of the PI in patients with reperfusion of a vascular compromised digit is a useful tool to continuously monitor peripheral perfusion. The dynamic behavior of the PI is essential to detect perfusion disturbance.
Keywords: Replanted digits, microsurgery, perfusion index, monitoring
DOI: 10.3233/CH-238120
Journal: Clinical Hemorheology and Microcirculation, vol. 86, no. 1-2, pp. 143-152, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl