Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected articles from the 3rd Joint Meeting of The European Society for Clinical Hemorheology and Microcirculation (ESCHM) , The International Society for Clinical Hemorheology (ISCH) and The International Society of Biorheology (ISB), Regensburg, Germany, 28 – 30 September 2023
Guest editors: L. Prantl, A. Krueger-Genge and F. Jung
Article type: Research Article
Authors: Río Bártulos, Carolina; * | Pirl, Lukas | Lier, Dennis | Planert, Mathis | Hohmann, Juliane | El Mountassir, Abdelouahed | El Anwar, Mohamed | Wiggermann, Philipp
Affiliations: Insitut für Röntgendiagnostik und Nuklearmedizin, Städtisches Klinikum Braunschweig gGmbH, Braunschweig, Germany
Correspondence: [*] Corresponding author: Carolina Rio Bártulos, Institut für Röntgendiagnostik und Nuklearmedizin, Städtisches Klinikum Braunschweig gGmbH, Salzdahlumer str. 90, Braunschweig, Germany. E-mail: c.rio@skbs.de.
Abstract: BACKGROUND: The range of software available to radiologists has increased enormously with the advancement of AI. A good example of this is software to determine ASPECTS in the treatment of potential stroke patients. OBJECTIVE: In this study, two software packages (eASPECTS from Brainomix and VIA_ASPECTS from Siemens) were tested and compared for their performance in the daily clinical routine of a maximum care provider with a 24/7 stroke unit. METHODS: A total of 637 noncontrast CT images were obtained from consecutive patients with suspected stroke, of whom 73 were finally diagnosed with MCA infarction. Differences in agreement and quantification of agreement were analysed, as well as the correlation and sensitivity, specificity and accuracy compared to raters. RESULTS: Compared to VIA_ASPECTS, eASPECTS shows good agreement and strong correlation with the raters. VIA_ASPECTS has lower accuracy and low specificity than eASPECTS but a higher sensitivity. CONCLUSION: Both software products have the potential to be decision support tools for radiologists. There are, however, differences between the two software products in terms of their intended use.
Keywords: Acute ischaemic stroke, computed tomography, software comparison, artificial intelligence
DOI: 10.3233/CH-238105
Journal: Clinical Hemorheology and Microcirculation, vol. 86, no. 1-2, pp. 109-119, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl