Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Zuo, Dongshenga; b | Yang, Kefenga | Wu, Sizea; *
Affiliations: [a] Department of Ultrasound, The First Affiliated Hospital of Hainan Medical University, Haikou, China | [b] Department of Ultrasound, The Second Affiliated Hospital of Nanchang University, Nanchang, China
Correspondence: [*] Corresponding author: Size Wu, Department of Ultrasound, The First Affiliated Hospital of Hainan Medical University, No.31, Longhua Road, Haikou 570102, China. Tel.: +86 0898 66774347; E-mail: wsz074@aliyun.com. ORCID: 0000-0002-1086-764X.
Abstract: BACKGROUND:The contrast-enhanced ultrasound (CEUS) liver imaging reporting and data system (LI-RADS) is a relative new algorithm for hepatocellular carcinoma (HCC) assessment. OBJECTIVE:To validate the diagnostic efficiency of the intravascular perfusion based CEUS LI-RADS for HCC. METHODS:Archives of 873 patients with focal liver lesions (FLLs) undergoing CEUS were reviewed, and target images were read by two sonologists independently according to the CEUS LI-RADS. The diagnostic performance was calculated and compared. RESULTS:Assessment with reference to CEUS LI-RADS, 87 of 218 FLLs (39.9%) were categorized as LR-5, 131 of 218 FLLs (60.1%) were categorized as non-LR-5, 19 of 99 HCCs were categorized as non-LR-5, and 7 of 119 non-HCCs were categorized as LR-5. The sensitivity, specificity, AUROC, positive and negative predictive values of CEUS LI-RADS for diagnosing HCC were 80.81%(95%CI: 71.7%–88.0%), 94.1%(95%CI: 88.3%–97.6%), 0.87 (95%CI: 0.82–0.92), 91.9%(95%CI: 84.1%–96.7%), and 85.5%(95%CI: 78.3%–91.0%), respectively. CONCLUSIONS:The diagnostic efficiency of the intravascular perfusion based CEUS LI-RADS for the evaluation of HCCs is very good.
Keywords: Liver, focal liver lesion (FLL), hepatocellular carcinoma (HCC), contrast-enhanced ultrasound (CEUS), liver imaging reporting and data system (LI-RADS)
DOI: 10.3233/CH-211164
Journal: Clinical Hemorheology and Microcirculation, vol. 78, no. 4, pp. 429-437, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl