Article type: Research Article
Authors: Liang, Ming | Ou, Bing | Wu, Jiayi | Xiao, Xiaoyun | Ruan, Jingliang | Tian, Jing | Xu, Xiaolin | Wang, Bin | Yang, Haiyun | Luo, Baoming; *
Affiliations: Department of Ultrasound, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
Correspondence: [*] Corresponding author: Dr. Baoming Luo, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, No. 107 Yanjiang Road West, Guangzhou, 510120, China. E-mail: luobm@mail.sysu.edu.cn.
Abstract: OBJECTIVE:To evaluate the combined use of strain elastography (SE) and superb microvascular imaging (SMI) with grayscale ultrasound (US) according to the Breast Imaging Reporting and Data System (BI-RADS) classification for differentiating benign from malignant breast masses. METHODS:In total, 166 patients with 177 breast masses categorized as BI-RADS 3–5 were included in the study between April 2016 to September 2017. US, SMI and SE were performed to evaluate each mass. The following outcome measures were compared between US and the combinations of US, SMI, and SE: area under the receiver operating characteristic curve (AUC), sensitivity, specificity. RESULTS:The addition of SMI and SE to US increased the AUC from 0.816 to 0.948 (P < .001); and the specificity from 43.7% to 80.8% (P < .001), without a significant decrease in the sensitivity. Meanwhile, 66.1% (37 of 56) of the benign masses that were indicated for unnecessary biopsy were correctly changed to follow-up. CONCLUSIONS:The addition SMI and SE to US could improve the diagnostic performance in differentiating benign from malignant breast masses compared to US alone. When US was combined with SMI and SE, the specificity were increased, thus significantly reducing unnecessary biopsies.
Keywords: Breast cancer, superb microvascular imaging, strain elastography, ultrasonography
DOI: 10.3233/CH-190693
Journal: Clinical Hemorheology and Microcirculation, vol. 74, no. 4, pp. 391-403, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl