Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Special Section: The ESCHM “1st Hemorheology Days”, 19 - 21 July 2017, Puchberg/Schneeberg, Austria
Article type: Research Article
Authors: Dibiasi, Christopha | Plewka, Jacekb | Ploszczanski, Leonb | Glanz, Veronikaa | Lichtenegger, Helgab | Windberger, Ursulaa; *
Affiliations: [a] Department of Biomedical Research, Decentralized Biomedical Facilities, Medical University of Vienna, Austria | [b] Department of Material Sciences and Process Engineering, Institute of Physics and Materials Science, University of Natural Resources and Life Sciences, Vienna, Austria
Correspondence: [*] Corresponding author: Ursula Windberger, Department of Biomedical Research, Decentralized Biomedical Facilities, Medical University of Vienna, Borschkegasse 8a, 1090 Vienna, Austria. Tel.: +43 0 1 40160 37103; E-mail: ursula.windberger@meduniwien.ac.at.
Abstract: BACKGROUND:Although the coagulation system is evolutionary well preserved, profound species differences exist in viscoelastic as well as in common laboratory tests of coagulation. OBJECTIVE:Evaluating differences in clot formation and material characterisation of clots of four mammalian species on macro-, micro- and nanoscales by the means of rheometry, scanning electron microscopy (SEM) and small angle x-ray scattering (SAXS). METHODS:Blood samples were collected from healthy human volunteers, laboratory rats (HL/LE inbred strain), warmblood horses and dromedary camels. Clot formation was observed by oscillating shear rheometry until plateau formation of the shear storage modulus G’, at which point selected clots were prepared for scanning electron microscopy. SEM images were analysed for fibre diameter and fractal dimension. Additionally, scattering profiles for plasma and whole blood samples were obtained with SAXS. RESULTS:Viscoelasticity of clots showed great interspecies variation: clots of rats and horses exhibited shorter clotting times and higher G’ plateau values, when compared to human clots. Camel clots showed unique clotting characteristics with no G’ plateau formation in the timeframe observed. Less differentiating features were found with SEM and SAXS, although the rat fibre network appears to be more convoluted and dense, which resulted in a higher fractal dimension. CONCLUSION:Clotting kinetic differs between the species, which is not only of clinical interest, but could also be an important finding for animal models of blood coagulation.
Keywords: Blood coagulation, rheometry, ROTEM, SEM, SAXS, comparative hemorheology
DOI: 10.3233/CH-189203
Journal: Clinical Hemorheology and Microcirculation, vol. 69, no. 4, pp. 515-531, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl