Article type: Research Article
Authors: Pu, Huana; b | Zhang, Xue-Lic | Xiang, Li-Huaa; b | Zhang, Jiu-Longc | Xu, Guanga; b | Liu, Huia; b | Tang, Guang-Yuc | Zhao, Bing-Huic | Wu, Ronga; b; *
Affiliations: [a] Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Tongji University School of Medicine, Shanghai, China | [b] Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, China | [c] Department of Radiology, Shanghai Tenth People’s Hospital, Tongji University School of Medicine, Shanghai, China
Correspondence: [*] Corresponding author: R. Wu, MD, PhD, Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, China. Tel.: +86 21 66301031(O); E-mail: wurong7111@163.com.
Abstract: PURPOSE:To evaluate the efficacy of added shear wave elastography (SWE) in breast screening for women with results inconsistent between mammography and conventional ultrasounds (US). MATERIALS AND METHODS:The study consisted of 282 pathologically proven breast lesions. The cancer probability from screening by mammography and conventional US were scored using Breast Imaging Reporting and Data System (BI-RADS). Elastography was used to re-evaluate inconsistent conventional US and mammography results. The diagnostic performance of conventional US, mammography, and Combined conventional clinical imaging and SWE was compared. The clinicopathological features of all breast cancer patients with inconsistent (and consistent) conventional US and mammography findings were compared. RESULT:Finally, 147 lesions were confirmed benign and 135 were malignant. The AUC of Combined conventional clinical imaging plus elastography imaging (0.870) was significantly higher than mammography (0.735, p < 0.001) or conventional US (0.717, p < 0.001) alone. Among the 135 breast cancers, 79 of the conventional US and mammography findings were consistent and 56 were inconsistent. Younger age(<50y) (p = 0.035), non-invasive (p = 0.037), smaller size (p = 0.002) and negative lymph node status (p = 0.026) were significantly associated with inconsistent findings. CONCLUSION:The added SWE in breast screening when inconsistent results from mammography and conventional US occurred is necessary and effective.
DOI: 10.3233/CH-180398
Journal: Clinical Hemorheology and Microcirculation, vol. 71, no. 1, pp. 83-94, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl