Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected papers of the 36th Conference of the German Society for Clinical Microcirculation and Hemorheology, 5–8. June, 2017, Greifswald, Germany
Guest editors: M. Jünger, A. Krüger-Genge and F. Jung
Article type: Research Article
Authors: Kehrer, Andreasa; * | Mandlik, Veronikaa | Taeger, Christiana | Geis, Sebastiana | Prantl, Lukasa | Jung, Ernst-Michaelb
Affiliations: [a] Department of Plastic, Hand and Reconstructive Surgery, University Medical Center Regensburg, Germany | [b] Department of Radiology, University Medical Center Regensburg, Germany
Correspondence: [*] Corresponding author: Dr. Andreas Kehrer, Department of Plastic, Hand and Reconstructive Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany. Tel.: +49 0 941 944 0; E-mail: AndreasKehrer@gmx.de.
Abstract: BACKGROUND AND OBJECTIVES:Facial paralysis causes excruciating impairments including facial asymmetry, limited eye closure, oral incontinence and social dysfunction. Modern plastic surgical reconstructions render favorable results with well-perfused dynamic muscle flaps. Post-operative tissue monitoring is a critical determinant for success. Contrast-enhanced Ultrasound (CEUS) and elastography have proven superior properties to evaluate tissue perfusion in various organs. We evaluated their role for functional muscle flaps positioned at the sub-skin level in facial palsy patients. METHODS:From 2016–2017 five patients received muscle flap reconstructions. Flaps included four free transplants and one pedicled transfer. Postoperatively tissue vitality and blood flow were assessed with CEUS. One experienced examiner using linear probes (6–9, 6–15 MHz) and bolus injections of Sulphur-hexafluoride microbubbles evaluated tissue perfusion. Using the time intensity curve- (TIC)-analysis measurements were recorded for TTP (time to peak) and AUC (Area under curve). Tissue elasticity was assessed with ultrasound elastography. RESULTS:All flaps were successful and showed no major complications. TTP-values in flap tissue showed slightly decreased values of 35.12±33.99 s and 25.04±10.86 s compared to surrounding tissue with 19.88±6.94 s. AUC-analysis however revealed higher values of 292.25±169.52 RU and 274.51±115.88 RU than surrounding tissue with 150.90±40.21 RU. Elastography demonstrated predominantly elastic flap tissue whereas surrounding tissue confirmed a slightly harder tissue quality. CEUS in combination with elastography verified tissue vitality and blood flow in a safe and reproducible manner. CONCLUSIONS:Post-operative perfusion monitoring in muscle flaps positioned at a sub-skin level may be performed superiorly by CEUS and elastography in a quick, reproducible and minimally-invasive fashion.
Keywords: Facial paralysis, functional muscle flaps, contrast-enhanced ultrasound (CEUS), elastography, tissue perfusion monitoring, blood flow
DOI: 10.3233/CH-179224
Journal: Clinical Hemorheology and Microcirculation, vol. 67, no. 3-4, pp. 435-444, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl