Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Mishra, Raghwendraa; b | Sarkar, Debasishc | Bhattacharya, Sourava | Mallick, Sanjayad; e | Chakraborty, Mousumia | Mukherjee, Debaratia; b | Kar, Manojb | Mishra, Roshnaraa; *
Affiliations: [a] Department of Physiology, University of Calcutta, Kolkata, India | [b] Department of Biochemistry, NRS Medical College, Kolkata, India | [c] Department of Chemical Engineering, University of Calcutta, Kolkata, India | [d] CU BD Centre of Excellence for Nanobiotechnology, University of Calcutta, Kolkata, India | [e] BD Biosciences, Salt Lake, Sector V, Kolkata, India
Correspondence: [*] Correspondence to: Roshnara Mishra, Assistant Professor, Department of Physiology, University of Calcutta, 92, A.P.C. Road, Kolkata-700009, India. Tel.: +91 33 23508386/6387/6396/1397 (Extn: 226); Fax: +91 33 2351 9755/2241 3288; roshnaramishra@gmail.com
Abstract: Studies of RBC morphological alterations, despite their potential clinical and experimental application, are compromised due to lack of simple and rapid techniques. As a complementary approach toward quantitative microscopy, we have reconstituted morphological information from light scattering data obtained from flow cytometer. Normal and poikilocytic agent treated samples were analyzed by microscopy and respective morphological index (MI) was calculated from the morphology based scores assigned to RBC. The samples were simultaneously analyzed by flowcytometer and the scatter data were obtained. Accordingly, the best correlated parameters of both forward scatter and side scatter were chosen to formulate a suitable regression model with MI as response. Flow cytometry data was also verified with another instrument (BD FACS Verse) and the equation obtained was validated with separate set of samples. The multivariate regression analysis yields a quadratic model with MI as response (R2 = 0.96, p < 0.001). The flow cytometric data from both instruments were in good agreement (Intra class correlation ∼0.9, p < 0.001). The model was found to simulate the sample MI with high accuracy (R2 = 0.97, p < 0.001). This proposed method was verified to be simple, rapid, quantitative and cost effective for the measurement of morphological alteration of RBC.
Keywords: Red blood cell, morphological alteration, morphological index, light scattering, flow cytometry
DOI: 10.3233/CH-131726
Journal: Clinical Hemorheology and Microcirculation, vol. 59, no. 4, pp. 287-300, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl