Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected papers of the 18th European Conference for Clinical Hemorheology and Microcirculation (ESCHM), 5-8 June, 2016, Lisbon, Portugal
Article type: Research Article
Authors: Wiesinger, I.a; * | Kroiss, E.a | Zausig, N.a | Hornung, M.b | Zeman, F.c | Stroszczynski, C.a | Jung, E.M.a
Affiliations: [a] Department of Radiology, University Medical Center Regensburg, Regensburg, Germany | [b] Department of Surgery, University Medical Center Regensburg, Regensburg, Germany | [c] Center of Clinical Studies, University Medical Center Regensburg, Regensburg, Germany
Correspondence: [*] Corresponding author: Dr. Isabel Wiesinger, Department of Radiology, University Hospital Regensburg, Franz Josef – Strauß – Allee 11 93053 Regensburg, Germany. Tel.: +49 941 944 7410; Fax: +49 941 944 7402; E-mail: Isabel.wiesinger@ukr.de.
Abstract: AIM: To determine different perfusion characteristics of histo-pathologically proven adenomas and carcinomas of the thyroid gland with CEUS and perfusion software. MATERIAL AND METHODS: Retrospective perfusion analysis of 25 patients with carcinomas and 41 cases of adenomas of the thyroid gland (30 males, 36 females; aged 18 – 85 years, mean 56 years). All cases were histologically analyzed. Perfusion analysis was independently performed using external perfusion software (VueBox®). TTP, mTT, Peak and Rise time were calculated. RESULTS: Lesions’ sizes ranged from 0.2 to 10.2 cm in carcinomas (mean 2.18 cm), and from 0.6 to 5.0 cm in adenomas (mean 2.25 cm). In 20 out of 25 carcinomas that were evaluated with CEUS, a complete wash-out in the late venous phase was found. Adenomas showed wash-out at the border. Perfusion analysis in VueBox® revealed some parameters which tend to show differences between adenomas and carcinomas, however did not reach the level of significance. Median Peak in carcinomas was highest at the margins (2945 rU), and lowest in the surroundings (1110 rU). Mean Transit Time (mTT) values showed no differences between center, margin and surrounding. In adenomas healthy tissue showed higher mTT values compared to the center (24.6 vs. 20.7 sec). Median Peak was highest in the surrounding tissue and lowest in the margins (1999 vs. 1129 rU). No statistical differences could be found in the comparisons. CONCLUSION: CEUS with perfusion analysis offers new possibilities for the dynamic evaluation of micro-vascularization in thyroid adenomas and carcinomas. Using VueBox® the perfusion analysis of the arterial phase provides new parameters that help determine a lesion’s malignancy or benignity. However a final assessment regarding malignancy and benignity of thyroid lesions using only CEUS and perfusion analysis of the arterial phase is not yet possible.
Keywords: Thyroid, CEUS, perfusion, micro-vascularization
DOI: 10.3233/CH-168044
Journal: Clinical Hemorheology and Microcirculation, vol. 64, no. 4, pp. 747-755, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl