Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected papers of the 18th European Conference for Clinical Hemorheology and Microcirculation (ESCHM), 5-8 June, 2016, Lisbon, Portugal
Article type: Research Article
Authors: Trottmann, M.a; * | Rübenthaler, J.b | Marcon, J.a | Stief, C.G.a | Reiser, M.F.b | Clevert, D.A.b
Affiliations: [a] Department of Urology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany | [b] Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
Correspondence: [*] Corresponding author: Dr. Matthias Trottmann, M.D., Department of Urology, Hospital of the Ludwig-Maximilians-University of Munich – Großhadern Campus, Marchioninistr. 15, 81377 Munich, Germany. Tel.: +4989/4400-0; E-mail: julian.marcon@med.uni-muenchen.de.
Abstract: PURPOSE: To investigate the difference of standard values of Supersonic shear imaging (SSI) and Acoustic Radiation Force Impulse (ARFI) technique in the evaluation of testicular tissue stiffness in vivo. MATERIALS AND METHODS: 58 healthy male testes were examined using B-mode sonography and ARFI and SSI. B-mode sonography was performed in order to scan the testis for pathologies followed by performance of real-time elastography in three predefined areas (upper pole, central portion and lower pole) using the SuperSonic® Aixplorer ultrasound device (SuperSonic Imagine, Aix-en-Provence, France). Afterwards a second assessment of the same testicular regions by elastography followed using the ARFI technique of the Siemens Acuson 2000™ ultrasound device (Siemens Health Care, Germany). Values of shear wave velocity were described in m/s. Parameters of elastography techniques were compared using paired sample t-test. RESULTS: The values of SSI were all significantly higher in all measured areas compared to ARFI (p < 0.001 to p = 0.015). Quantitatively there was a higher mean SSI wave velocity value of 1,1 compared to 0.8 m/s measured by ARFI. CONCLUSION: SSI values are significantly higher than ARFI values when measuring the stiffness of testicular tissue and should only be compared with caution.
Keywords: Testis, shear-wave elastography, ultrasonography
DOI: 10.3233/CH-168039
Journal: Clinical Hemorheology and Microcirculation, vol. 64, no. 4, pp. 729-733, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl