Authors: Rennert, Janine | Farkas, Stefan | Georgieva, Martina | Loss, Martin | Dornia, Christian | Jung, Wolfgang | Stroszczynski, Christian | Jung, Ernst-Michael
Affiliations: Department of Radiology, University Medical Center Regensburg, Regensburg, Germany | Department of Surgery, University Medical Center Regensburg, Regensburg, Germany | Department of Materials Research, University of Saarbruecken, Saarbruecken, Germany
Note: [] Corresponding author: Janine Rennert, M.D, Department of Radiology, University Medical Center Regensburg, Franz-Josef-Strauss Allee 11, 93053 Regensburg, Germany. Tel.: +49 941 944 7401; Fax: +49 941 944 7402; E-mail: jarennert@yahoo.de
Abstract: AIM: Identification of acute and subacute complications following pancreas and renal transplantation using contrast enhanced ultrasound (CEUS) in comparison with Magnetic Resonance Tomography (MRI), Computed Tomography (CT), Digital Subtraction Angiography (DSA) or Ultrasound (US). The study evaluated whether CEUS could confirm the preliminary diagnosis or even provide additional information, relevant for the therapeutic strategy. MATERIAL AND METHODS: Retrospective evaluation of 19 patients (13 male, 6 female, age 26–77 years, mean 53.2 years) following renal transplantation and 10 patients (4 male, 6 female, age 35–56 years, mean 45.7 years) following combined pancreas and renal transplantation. CEUS was used as an additional diagnostic method when obscure diagnostic findings occurred in US, CT, MRI or DSA. Fundamental B-scan, Color Coded Doppler Sonography (CCDS) and CEUS were performed in all patients by an experienced examiner using a multifrequency convex transducer (1–5 MHz). After a bolus injection of up to 2.4 ml SonoVue® [BRACCO, Italy] digital raw data was stored as cine-loops up to 5 minutes in length. RESULTS: In all patients, the pathological features and suspected diagnostic findings identified in the other imaging modalities could be confirmed using CEUS (100%). In 25 out of 29 patients (86.2%), new clinically relevant findings were detected. In 27 patients, the diagnosis of CEUS was confirmed during surgery (7), DSA (5), follow-up CEUS (13), CT (1) and MRI (1). In 4 patients renal AV-fistulas were found following biopsy, 3 patients showed post-operative allograft arterial stenosis or dissection, 1 patient demonstrated a stenosis of the common iliac artery and 2 patients were diagnosed with post-operative allograft venous thrombosis or stenosis. In 2 patients, a definite diagnosis of a benign lesion following renal transplantation was possible. In 1 patient a malignant lesion was suspected and confirmed following surgery. In 6 patients, normal perfusion of the pancreas and renal parenchyma and the corresponding vessels was diagnosed, in 5 patients the parenchymal perfusion was diminished and 1 patient suffered from pancreatitis. CONCLUSION: These first results show that CEUS can provide additional, clinically relevant informations in patients with acute and subacute complications following pancreas and renal transplantation. Thus, an early application within the diagnostic course seems favorable.
Keywords: Contrast enhanced ultrasound (CEUS), pancreas transplantation, renal transplantation, complications
DOI: 10.3233/CH-131675
Journal: Clinical Hemorheology and Microcirculation, vol. 58, no. 2, pp. 343-352, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl