Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Bronkhorst, Philippine J.B. | Berends, Gerard | Bardeman, Max R. | Nijhof, Evert Jan | Sixma, Jan J.
Affiliations: Dept of Haematology | Helmholtz Instituut, Dept. Physics of Man, University of Utrecht | Dept. of Internal Medicine, University of Amsterdam. Dept. of Haematology, Univ. Hospital, G.03.647, P.O. Box 85500 GA Utrecht, The Netherlands
Abstract: Measurements of red cell deformability are usually performed in isotonic buffer solutions as suspending medium. However, in vivo, red cells are surrounded by plasma in which plasma proteins are present. In this study we investigated whether using plasma (anticoagulated with 1/10 vol. 110 mM trisodium citrate) instead of buffer (phosphate buffered saline solution) as the suspending medium gives rise to differences in the measured red cell deformability parameters. We used ektacytometry, the micropipette, the flow channel (both static and dynamic), and a Cell Transit Analyzer to study this effect. Where necessary, we added 1 g/l bovine serum albumin to prevent echinocyte formation, and poly-vinyl-pyrrolidone to increase the buffer viscosity to match that of plasma. Plasma was found to be a good alternative for buffer as suspending medium except for ektacytometric measurements. In ektacytometry, interactions between plasma components and the polymer added to increase the medium viscosity caused measurement artefacts. Comparison between the plasma and the buffer measurements using the other techniques showed a decreased red cell deformability in plasma. We found that in plasma membrane elasticity is decreased and membrane viscosity is increased compared with buffer (from micropipette and flow channel measurements) and a decreased filterability in plasma with the Cell Transit Analyzer. It is unclear whether the plasma composition or the buffer composition is responsible for the observed increased membrane viscosity and decreased membrane elasticity in plasma or, in other words, the decreased viscosity and increased elasticity in buffer. However, our results raise the question whether buffer is a good medium and whether deformability studies in general should be performed in plasma instead of in buffer.
Keywords: ektacytometry, flow channel, micropipette, Cell Transit Analyzer, plasma, red cell deformability
DOI: 10.3233/CH-1996-16207
Journal: Clinical Hemorheology and Microcirculation, vol. 16, no. 2, pp. 151-163, 1996
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl