Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Papers of the 31st Conference of the German Society for Clinical Microcirculation and Hemorheology, Halle, Germany, 15–16 June 2012
Article type: Research Article
Authors: Clevert, D.A. | Paprottka, P.M. | Helck, A. | Reiser, M. | Trumm, C.G.
Affiliations: Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, Munich, Germany
Note: [] Corresponding author: Priv.-Doz. Dr. med. Dirk-André Clevert, Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, 81377 Munich, Germany. Tel.: +49 89 7095 3620; Fax: +49 89 7095 8832; E-mail: Dirk.Clevert@med.uni-muenchen.de
Abstract: Purpose: The purpose of this study was to evaluate whether image fusion with contrast enhanced ultrasound (CEUS) and CT is effective in the pre-, intra- and post-interventional management of liver lesions during microwave or radiofrequency ablation. Methods and materials: Fifteen patients with a single hepatocellular carcinoma (HCC) up to 3 cm diameter, identified on both contrast-enhanced CT (Siemens Somatom Definition AS and Definition Edge, Siemens Healthcare, Erlangen, Germany) and ultrasound (Siemens ACUSON S2000™ or S3000™, Siemens Healthcare, Erlangen, Germany) were retrospectively enrolled between July 2011 and May 2012. Either automatic registration or plane match registration was chosen on CT and ultrasound for the pre-, intra- and postinterventional management of all treated liver lesions during microwave or radiofrequency ablation. Using conventional ultrasound B-mode, CEUS and image fusion including B-mode and CEUS the detectability of the liver lesions was evaluated semi-quantitatively by comparing the image sequences in a consensus reading. Eight patients underwent radiofrequency ablation and seven patients underwent microwave ablation. Results: All patients were examined using all diagnostic ultrasound tools of the study. The results show that the procedure is easy and convenient to perform, as well as efficient. The co-registration procedure took approximately 5 to 10 minutes depending on the amount of DICOM volume-data and the habitus of the patient. The results show that the use of image fusion with CT and contrast-enhanced ultrasound could improve the diagnostic assessment capabilities in comparison to the examination without image fusion in the pre-, intra- and postinterventional management of malignant liver lesions during thermal ablation. Conclusion: Percutaneous thermal ablation guided by contrast-enhanced ultrasound and image fusion seems to be an efficient approach for malignant liver lesions especially if these are not clearly demarcated by B-mode. The use of the image fusion technique in the pre-, intra- and postinterventional management can increase operator confidence, the accuracy of the procedure, and technical success in real time.
Keywords: Image fusion, radiofrequency ablation, microwave ablation, interventional radiology, hepatocellular carcinoma
DOI: 10.3233/CH-2012-1598
Journal: Clinical Hemorheology and Microcirculation, vol. 52, no. 2-4, pp. 205-216, 2012
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl