Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Jünger, Michael | Haase, Hermann | Schwenke, Linda | Bichel, Jens | Schuren, Jan | Ladwig, Andrea
Affiliations: University of Greifswald, Greifswald, Germany | 3M Deutschland GmbH, Neuss, Germany
Note: [] Corresponding author: Michael Jünger, MD, PhD, F. Sauerbruchstr, D-17475 Greifswald, Germany. E-mail: juenger@uni-greifswald.de
Abstract: Objective: To investigate macro- and microperfusion during 14 days of treatment with a new 2-layer compression system (3M™ Coban™ 2 Lite), designed for patients with leg ulcer and concomitant peripheral arterial occlusive disease. Methods: A single-centre, open-label, prospective pilot study was performed with 15 subjects suffering from peripheral arterial occlusive disease with an ankle brachial pressure index (ABPI) of 0.5–0.8, who volunteered to have their ‘study leg’ bandaged with the new system. Coincident leg ulcer or chronic venous disease was not mandatory. All subjects received the new compression system, which stayed in place from 1 up to 4 days according to scheduled study visits. The system was reapplied by study personnel at each clinical visit (days 1, 2, 3, 4, 7, 10 and 14). The study participation stopped after 14 days. At each clinical visit safety assessments were performed: measurement of acral pulsation to capture macroperfusion; laser Doppler fluxmetry to capture microperfusion; clinical signs of pressure related skin damage, hypoxia-related pain and sub-bandage pressure measurement. In addition, the leg volume was measured and a comfort questionnaire was completed. Results: An average sub-bandage pressure in standing position of approximately 30 mmHg was measured at the B1 location immediately after bandage application. Laser Doppler fluxmetry demonstrated positive effects on microcirculation regarding vasomotion and respiratory reflux. No change of the cardiac signal appeared. For acrale pulsations a high intraindividual variability was found with no clear interference to the bandage application. No pressure-related skin damage or hypoxia-related pain was detected. Conclusion: After application of the new compression system in subjects with moderate PAOD, laser Doppler fluxmetry indicated significant improvements of the microcirculation. High variability and lack of correlation to clinical symptoms was found for the acral pulsation. The new compression system revealed a high grade of tolerability and a good safety profile.
Keywords: Leg ulcer , pressure-related skin damage
DOI: 10.3233/CH-2012-1568
Journal: Clinical Hemorheology and Microcirculation, vol. 53, no. 3, pp. 281-293, 2013
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl