Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kaiser, Ralf | Grotemeyer, Katharina | Kälsch, Thorsten | Gräber, Stefan | Wilkens, Heinrike | Elmas, Elif
Affiliations: Department of Pulmonology, Saarland University, Homburg/Saar, Germany | Department of Gastroenterology, Saarland University, Homburg/Saar, Germany | Department of Biometry, Epidemiology and Medical Informatics, Saarland University, Homburg/Saar, Germany | 1st Department of Medicine, University Medical Centre Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer, Mannheim, Germany
Note: [] Corresponding author: Ralf Kaiser, Department of Pulmonology, Saarland University, Homburg/Saar, Germany. E-mail: ralfkaiser@gmx.net
Abstract: BACKGROUND: TSP-1 is a vasoconstrictive protein, which is released from both endothelium and cardiomyocytes during ischemia and promotes platelet aggregation and adhesion to subendothelial layers in atherosclerotic lesions. During myocardial ischemia and reperfusion, TSP-1 disturbs local microcirculation by disrupting both NO-signaling as well as VEGF-pathways by activation of CD47 and CD36. Furthermore, activation of TGF-ß might induce excessive fibrosis after infarction. It was assumed that TSP-1 is washed out after successful coronary reperfusion. In this study, we examined circulating TSP-1 post emergency PCI as a risk factor for major adverse cardiac events after STEMI with and without ventricular fibrillation. METHODS: TSP-1 levels in platelet poor plasma were measured in 54 patients after ST-elevation myocardial infarction. Major adverse cardiac events were monitored for 426 days. RESULTS: Patients with decreased TSP levels after coronary stenting showed a significantly higher risk for MACE than patient with higher TSP levels (TSP-1[d0]: n = 46, no MACE = 16.38 ± 1.98 ug/mL vs. MACE 7.11 ± 1.54 ug/mL; p = 0.003). Kaplan-Meyer-analysis for MACE showed a better outcome above 10 ug/mL (p = 0.02). For MACE later than 3 months post-STEMI, the corresponding Kaplan-Meier-analysis yielded a p-value of 0.01. The number needed to diagnose for late MACE was 2.158. CONCLUSION: Low plasma levels of TSP1 after PCI are associated with MACE. Due to its procoagulant effects and dysregulation of microvascular tone, adequately powered prospective studies are warranted to test the impact of TSP-1 on cardiac microcirculation, endothelial function and remodeling. TSP-1 might serve as a new diagnostic and therapeutic approach in cardiovascular disease.
Keywords: Thrombospondin-1, ST-elevation myocardial infarction, major adverse cardiac events, percutaneous coronary intervention
DOI: 10.3233/CH-2012-1565
Journal: Clinical Hemorheology and Microcirculation, vol. 54, no. 1, pp. 59-73, 2013
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl