Article type: Research Article
Authors: Persson, Sylvi U.; | Hedner, Pavo
Affiliations: Department of Internal Medicine, University Hospital of Lund, S-221 85 Lund, Sweden
Note: [] Sylvi U. Persson, Department of Medicine, University Hospital, 8-221 85 Lund, Sweden.
Abstract: Erythrocyte deformability can be measured as filterability through a polycarbonate filter. To evaluate the influence of variations in filtration pressures the present study was performed as filtration of red cell suspensions with a pore size of 5 um at constant negative pressures of −10, −20, −30, −40 and −50 mm H2O in the St. George's Filtrometer. Filtration parameters were expressed as passage time, flow rate, flow resistance, initial relative filtration rate (IrFR) , red cell transit time (RCTT) and clogging particles (CP). Passage time was decreased and flow rate was increased significantly at all filtration pressures compared to preceding pressure level (p<0.001). In the pressure range −10 to −30 mm H2O flow resistance decresed significantly (p<0.001) , but was almost constant in the range −30 to −50 mm H2O. Also IrFR and RCTT showed a significantly greater change (p<0.001) when the pressure was increased from −10 to −20 mm H2O compared to the same pressure change in the range −30 to −50 mm H2O. CP varied more with pressure, but the greatest change was found in the range −10 to −20 mm H2O. Variations of MCV within the normal range were associated with changes in passage time, flow resistance and CP in the pressure range −20 to −50 mm H2O. It is concluded that the filtration pressure is an important factor in studies on blood cell filterability. For the St. George's Filtrometer the optimal pressure range seems to be −30 to −50 mm H2O.
Keywords: Erythrocyte filterability, filtration test, stress factors, filtration pressure, wall shear stress, mean corpuscular volume, mean corpuscular hemoglobin concentration
DOI: 10.3233/CH-1993-13611
Journal: Clinical Hemorheology and Microcirculation, vol. 13, no. 6, pp. 791-801, 1993
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl