Abstract: The in vitro hemorheological effects of three new, so called low osmolar, radio-contrast media (CM) were compared. Two of the CM were non-ionic compounds, Iohexol and Iopamidol, the third one was the ionic dimer Ioxaglate. Their osmolalities varied from 574 to 679 mosmol/kg. with viscosities from 4.8 to 7.5 mPa.s. Red blood cell (RBC) aggregation (syllectometry and calCulation of the aggregation factor, AF), RBC deformability (ektacytometry and calculation of the Taylor factor, Tk), plasma viscosity as well as low and high shear viscosity of various blood-CM mixtures were measured. Changes in these parameters, induced by various grades of dilution and/or hyperosmolality were related to changes in morphological parameters, found in an earlier, comparable study. It was shown that, in contrast to both non-ionic CM and despite its own hyperosmolality, Ioxaglate had no effect on RBC morphology and caused less deterioration of RBC deformability and aggregation than hyperosmolar saline. So far no explanation has been found for this phenomenon. Transformation from normal RBC biconcave morphology to echinocytes due to a hyperosmolar environment was invariably associated with a decrease in elongation index (more rigid cells), disturbance of rouleau formation and an abnormal sylleetogram. The values of AF and Tk were not always consistent with the other parameters reflecting RBC aggregation and deformability.
Keywords: contrast medium, erythrocyte deformability, erythrocyte aggregation, blood viscosity
DOI: 10.3233/CH-1992-12304
Journal: Clinical Hemorheology and Microcirculation, vol. 12, no. 3, pp. 381-392, 1992
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl