Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: The Seventh International Congress of Biorheology. Part II, Clinical Hemorheology. Held at Palais des Congrès, Nancy, France, 18–23 June 1989
Guest editors: Alfred L. Copley and Jean-François Stoltz
Article type: Research Article
Authors: Hartert, H.
Affiliations: Richard-Wagner-Str. 1, 6750 Kaiserslautern, FRG
Note: [] Accepted by: Editor-in-Chief S. Witte
Abstract: Orbitometry (Hartert) is a rheological ex-vivo method to follow up physical assembly of a coagulum in layers during natural intensity of flow by orbital movement. Fibrin elasticity in the Orbitometers mode of Resonance Thrombography is differentiated from platelet activity as well as e.g. from the effects of disseminated coagulation – minimal in liver disease and maximal during disturbances of delivery. Transition into the mode of dynamic Tendography (Hartert) will e.g. register all fast going tests lasting minutes or seconds. It is comparable to an accelerated form of Thrombelastography (Hartert), the intercourse of which with coagulum yet is an exclusively static operation. Another category is measurement of blood and plasma viscosity. In concentrated blood it seizes plasticity of blood cells as well as their intensity of aggregation in orbital flow. The latest methodical development of Orbitometry is control of platelet activity in its function of adhesion. This is realized by measurement of specific physical effects released in platelet containing coagulum. They generate a structural degradation of fibrin elasticity modul as well as a tendency for coagulum adhesion. The practical use of Adhesiongraphy is control of anticoagulants and platelet protecting substances in their quantitative influence on coagulum structure and on the mentioned platelet activities. A special disturbance of these platelet depending mechanisms obviously is getting evidence in case of v.Willebrand’s syndrome.
Keywords: Orbitometer, fibrin elasticity, strain of flow, resonance, adhesiography, platelet shape change
DOI: 10.3233/CH-1990-10408
Journal: Clinical Hemorheology and Microcirculation, vol. 10, no. 4, pp. 401-409, 1990
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl