Article type: Research Article
Authors: Whale, M.D. | Grodzinsky, A.J. | Johnson, M.; *
Affiliations: Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
Correspondence: [*] Address for correspondence: Dr. M. Johnson, Room 3-264, M.I.T., 77 Massachusetts Avenue, Cambridge, MA 02139, USA; Tel.: (617) 253-7604; Fax: (617) 258-8559; E-mail: markj@mit.edu
Abstract: We measured the specific hydraulic conductivity (K) of the human and bovine aortic wall, two tissues for which K has not been previously reported in the literature, and examined the effects of aging (human) and development (bovine) on K. As part of the study, we also examined the effects of mounting the tissue in a flat or cylindrical configuration and the effects of perfusion pressure. With aging, in the human, we found a modest increase of K with age in a flat geometry; this trend was not apparent in a limited number of measurements in a cylindrical geometry. No significant dependence of K on developmental stage was found in the bovine aortic wall perfused in either a flat or cylindrical geometry. Our results indicate that aging and developmental changes of the aortic extracellular matrix have minimal effects on its hydrodynamic transport properties as measured. Mounting geometry for the aorta has been a concern reported in the literature since Yamartino et al. (1974) reported that K in the rabbit was 10-fold lower when measured in a flat geometry than in a cylindrical geometry. We found mounting geometry to make only a small difference in the calf and the cow, (Kflat approximately 2/3 of Kcylindrical), and in the human, we found K to be somewhat higher in the flat geometry than in the cylindrical geometry. Higher perfusion pressures decreased K of bovine tissue in the flat geometry, but pressure was not found to have a significant effect on K in the cylindrical geometry. An analytical model demonstrated that the anisotropic nature of the aortic wall allows it to be compressible (water-expressing) and yet remain at nearly constant tissue volume as the aorta is pressurized in a cylindrical geometry.
Keywords: Aorta, anisotropic, strain, permeability, compressible, perfusion
DOI: 10.3233/BIR-1996-33103
Journal: Biorheology, vol. 33, no. 1, pp. 17-44, 1996
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl