Article type: Research Article
Authors: Tomkiewicz, R.P. | Biviji, A. | King, M.
Affiliations: Pulmonary Research Group, 173 Heritage Medical Research Centre, University of Alberta, Edmonton, AB T6G 2S2 Canada
Abstract: This in vitro study addressed the question of clearance-related changes in the physical properties of mucous gel simulants (MGS) subjected to oscillating air flow. Delineating some of the possible mechanisms of action for the reported beneficial effects of high-frequency chest compression (HFCC) therapy constituted the rationale. The rheological variables measured were spinnability by filancemeter and viscoelasticity (mechanical impedance, G*, and loss tangent, tan δ) by magnetic microrheometry. Two derivative parameters, mucociliary clearability index (MCI) and cough clearability index (CCI), were computed from the rheological variables, based on relationships established from model studies of clearance. Two ranges of air flow oscillation frequencies used previously in animal and clinical studies, i.e., 12–13 Hz or 22–23 Hz, were applied. The measurements were made after application of oscillating air flow for 15, 30 and 60 minutes, and compared with those at baseline and negative control. A significant decrease in log G* with administration of oscillations was observed (p=0.06 at 30 minutes, p<0.01 at 60 minutes, for G* measured at 1 rad/s). Spinnability also decreased by 19.3% and 30.7% after 15 minutes; 32.9% and 41.1% after 30 minutes; 36.4% and 50.5% after 60 minutes, for 12 Hz and 22 Hz, respectively (all significantly different from baseline). There was a positive correlation between viscoelasticity and spinnability, and a negative correlation between spinnability and CCI, but no correlation between spinnability and MCI. Oscillating air flow seemed to act as a physical “mucolytic” that affected mostly the cough clear ability of the mucus simulant.
Keywords: High-frequency oscillation, mucus clearance, rheology
DOI: 10.3233/BIR-1994-31501
Journal: Biorheology, vol. 31, no. 5, pp. 511-520, 1994
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl