Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Nash, G.B.; *
Affiliations: Department of Haematology, St. George’s Hospital Medical School, London, UK
Note: [*] Current Address: Department Haematology, The Medical School, Birmingham B15 2TJ, UK.
Note: [] Accepted by: Editor-in-Chief S. Witte
Abstract: It could be claimed that expansion in clinical aspects of haemorheology has largely been fuelled by the development of a simple test of blood flow properties, i.e., analysis of filterability. With time, the level of sophistication in equipment, theory and sample preparation has increased. Theories for the development of flow in the filter have been described and these enable cellular parameters, such as transit times, to be calculated from experimental data. These theories can be quite general, and applied to filtration of red or white cells. Ideally, experimental design requires an understanding of cell behaviour at the filter and of the effects of factors such as the sample concentration and volume, and the presence of different types of cells or subpopulations. Otherwise, results are susceptible to misinterpretation, particularly if impurities or mixed populations of cells are present. It is thus very important to know accurately the constituents of the test suspension. In clinical applications the trend has been to move away from whole blood filtration, toward use of relatively pure suspension of separated red cells and white cells. In the area of red cell filtration this has led to reappraisal of some previously reported abnormalities. The relatively new study of white cell filtration should benefit from previous experience, but there is the added problem of the reactivity of the cells under test, and their mixed nature. In any case, critical evaluation of the meaning and clinical relevance of results is necessary.
Keywords: Red Blood Cells, White Blood Cells, Filterability
DOI: 10.3233/BIR-1990-27608
Journal: Biorheology, vol. 27, no. 6, pp. 873-882, 1990
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl