Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: 25th Anniversary Volume
Article type: Research Article
Authors: Litt, M.a; b | Kron, R.E.a; b | Litt, S.E.a; b
Affiliations: [a] KDL Technologies, Inc., Philadelphia, Pennsylvania, USA | [b] University of Pennsylvania, Philadelphia, Pennsylvania, USA
Note: [1] presented at the sixth International Congress of Biorheology, Vancouver, British Columbia, July 22 - August 1, 1986.
Note: [] Accepted by: Editor R. Skalak
Abstract: A disposable clinical whole blood viscometer which can produce viscosity measures over a wide range of shear rates in a single rapid determination has been developed and is currently under test. The design is based upon the time varying flow of blood through a capillary. The flow is driven by the pressure in a fixed volume air chamber and transmitted to the sample through a compliant membrane. The time varying pressure in the air chamber is measured by a suitable transducer. The instantaneous shear stress of the blood in the capillary is proportional to the air pressure, while the instantaneous shear rate is proportional to the pressure-time derivative. Proper design ensures that the system operates as a first order dynamic system with flow resistance entirely determined by the nonlinear sample viscosity. By constructing the air chamber in two parts coupled by a quick disconnect fitting the design can allow for the blood-containing part of the instrument to be discarded, eliminating handling and cleaning of blood contacted components. The entire determination is completed in less than a minute, so that anticoagulants are not necessary. Tests on a prototype show that the instrument gives results in excellent agreement with those obtained on a cone-plate rheogoniometer.
Keywords: blood, clinical, viscometer, disposable
DOI: 10.3233/BIR-1988-25409
Journal: Biorheology, vol. 25, no. 4, pp. 697-712, 1988
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl