Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Bilgi, Coşkuna | Atalık, Kunta;
Affiliations: [a] Mechanical Engineering Department, Boğaziçi University, Bebek, Istanbul, Turkey
Correspondence: [*] Corresponding author: Kunt Atalık, Mechanical Engineering Department, Boğaziçi University, 34342 Bebek, Istanbul, Turkey. E-mail: atalik@boun.edu.tr
Abstract: BACKGROUND:Previous studies on aneurysm modeling have focused on the blood rheology and vessel elasticity separately. The combined effects of blood shear thinning properties and wall elasticity need to be revealed. OBJECTIVE:To provide insights on how pulsatile hemodynamics vary with blood rheology and vessel elasticity for a developed abdominal aortic aneurysm (AAA). METHOD:An Arbitrary Lagrangian-Eulerian fluid-solid interaction method is adopted with the Newtonian and the shear thinning Carreau constitutive models for the fluid with the linearly elastic and the hyperelastic Yeoh models for the vessel. Finite element based numerical solver is used to simulate the blood flow in the AAA. RESULTS:Newtonian model overestimates the velocity values compared to the Carreau model and the difference in the velocity field increases as the shear rate decreases at the instances of the cardiac cycle. The rigid walled simulations display higher deviations in the velocity and wall shear stress with the fluid rheology. The risk indicators show that Newtonian assumption combined with the linearly elastic model may overlook degeneration risk of arterial tissue. CONCLUSIONS:Newtonian assumption for the blood as well as modelling the arterial wall as linearly elastic lead to significant differences in oscillatory hemodynamic properties with respect to the use of Carreau fluid together with hyperelastic vessel model, even in large vessel aneurysms.
Keywords: Pulsatile hemodynamics, fluid-solid interaction (FSI), abdominal aortic aneurysm (AAA), blood rheology, blood vessel modeling, oscillatory shear index (OSI)
DOI: 10.3233/BIR-180202
Journal: Biorheology, vol. 56, no. 1, pp. 51-71, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl