Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Chen, Chih‐Tung; ; | Malkus, David S. | Vanderby Jr., Ray; ;
Affiliations: University of Wisconsin, Division of Orthopedic Surgery, Madison, WI 53792, USA | University of Wisconsin, Department of Mechanical Engineering, Madison, WI 53706, USA | Department of Engineering Physics, Madison, WI 53706, USA | James A. Baker Institute for Animal Health, Cornell University, Ithaca, NY 14853, USA
Abstract: Collagen fibrils in ligaments and tendons are highly organized into parallel arrays which influence interstitial fluid transport. Finite element (FE) models were developed analogous to the fibrillar arrays in ligaments and tendons to investigate interstitial fluid flow and tissue permeability as a function of interfibrillar spacing and fluid properties. Collagen fibrils were assumed to be a periodic square array of impermeable cylinders. A two‐dimensional FE model was used to study transverse fluid flow and a three‐dimensional model was used to study flow parallel to the collagen fibrils. Parametric FE analysis provided data to formulate empirical expressions for permeability (\kappa) as a function of porosity (\phi). Results show that longitudinal permeability (\kappa=1.1\cdot 10^{-15} \phi^{2.5}[1-\phi]^{-0.333}) can be up to 50 times higher than transverse permeability (\kappa=1.2\cdot 10^{-15} \phi^{0.5}[\phi-\phi_{\min}]^{2.5}) in a compact array. Maximum fluid shear stresses occur at the narrowest zones of adjacent fibrils (1.21 Pa or 12.1 dyn/cm^{2} at 10 \mum/s of average transverse influx). If interstitial fluid is highly non‐Newtonian, the permeability should be considered as flow (shear)‐dependent. The computational results suggest that tissue permeability in ligaments and tendons is highly anisotropic, porosity‐dependent, and can be estimated by analytic expressions.
Keywords: Finite element analysis, ligaments and tendons, interstitial fluid, tissue permeability, non‐Newtonian fluid
Journal: Biorheology, vol. 35, no. 2, pp. 103-118, 1998
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl