Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Purchase individual online access for 1 year to this journal.
Price: EUR 160.00Authors: Tan, Wenjun | Huang, Peifang | Li, Xiaoshuo | Ren, Genqiang | Chen, Yufei | Yang, Jinzhu
Article Type: Research Article
Abstract: Precise segmentation of lung parenchyma is essential for effective analysis of the lung. Due to the obvious contrast and large regional area compared to other tissues in the chest, lung tissue is less difficult to segment. Special attention to details of lung segmentation is also needed. To improve the quality and speed of segmentation of lung parenchyma based on computed tomography (CT) or computed tomography angiography (CTA) images, the 4th International Symposium on Image Computing and Digital Medicine (ISICDM 2020) provides interesting and valuable research ideas and approaches. For the work of lung parenchyma segmentation, 9 of the 12 participating …teams used the U-Net network or its modified forms, and others used the methods to improve the segmentation accuracy include attention mechanism, multi-scale feature information fusion. Among them, U-Net achieves the best results including that the final dice coefficient of CT segmentation is 0.991 and the final dice coefficient of CTA segmentation is 0.984. In addition, attention U-Net and nnU-Net network also performs well. In this paper, the methods chosen by 12 teams from different research groups are evaluated and their segmentation results are analyzed for the study and references to those involved. Show more
Keywords: Deep learning, computed tomography (CT), computed tomography angiography (CTA), segmentation of lung parenchyma, U-Net, nnU-Net
DOI: 10.3233/XST-210956
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 6, pp. 945-959, 2021
Authors: Rajakumar, M.P. | Sonia, R. | Uma Maheswari, B. | Karuppiah, SP.
Article Type: Research Article
Abstract: World-Health-Organization (WHO) has listed Tuberculosis (TB) as one among the top 10 reasons for death and an early diagnosis will help to cure the patient by giving suitable treatment. TB usually affects the lungs and an accurate bio-imaging scheme will be apt to diagnose the infection. This research aims to implement an automated scheme to detect TB infection in chest radiographs (X-ray) using a chosen Deep-Learning (DL) approach. The primary objective of the proposed scheme is to attain better classification accuracy while detecting TB in X-ray images. The proposed scheme consists of the following phases namely, (1) image collection and …pre-processing, (2) feature extraction with pre-trained VGG16 and VGG19, (3) Mayfly-algorithm (MA) based optimal feature selection, (4) serial feature concatenation and (5) binary classification with a 5-fold cross validation. In this work, the performance of the proposed DL scheme is separately validated for (1) VGG16 with conventional features, (2) VGG19 with conventional features, (3) VGG16 with optimal features, (4) VGG19 with optimal features and (5) concatenated dual-deep-features (DDF). All experimental investigations are conducted and achieved using MATLAB® program. Experimental outcome confirms that the proposed system with DDF yields a classification accuracy of 97.8%using a K Nearest-Neighbor (KNN) classifier. Show more
Keywords: Tuberculosis, chest X-ray, VGG16, VGG19, mayfly algorithm, dual-deep-features.
DOI: 10.3233/XST-210976
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 6, pp. 961-974, 2021
Authors: Chen, Buxin | Zhang, Zheng | Xia, Dan | Sidky, Emil Y. | Pan, Xiaochuan
Article Type: Research Article
Abstract: BACKGROUND: Interest exists in dual-energy computed tomography (DECT) imaging with scanning arcs of limited-angular ranges (LARs) for reducing scan time and radiation dose, and for enabling scan configurations of C-arm CT that can avoid possible collision between the rotating X-ray tube/detector and the imaged subject. OBJECTIVE: In this work, we investigate image reconstruction for a type of configurations of practical DECT interest, referred to as the two-orthogonal-arc configuration, in which low- and high-kVp data are collected over two non-overlapping arcs of equal LAR α, ranging from 30° to 90°, separated by 90°. The configuration can readily be implemented, …e.g., on CT with dual sources separated by 90° or with the slow-kVp-switching technique. METHODS: The directional-total-variation (DTV) algorithm developed previously for image reconstruction in conventional, single-energy CT is tailored to enable image reconstruction in DECT with two-orthogonal-arc configurations. RESULTS: Performing visual inspection and quantitative analysis of monochromatic images obtained and effective atomic numbers estimated, we observe that the monochromatic images of the DTV algorithm from LAR data are with substantially reduced LAR artifacts, which are observed otherwise in those of existing algorithms, and thus visually correlate reasonably well, in terms of metrics PCC and nMI, with their reference images obtained from full-angular-range data. In addition, effective atomic numbers estimated from LAR data of DECT with two-orthogonal-arc configurations are in reasonable agreement, with relative errors up to ∼ 10%, with those estimated from full-angular-range data in DECT. CONCLUSIONS: The results acquired in the work may yield insights into the design of LAR configurations of practical dual-energy application relevance in diagnostic CT or C-arm CT imaging. Show more
Keywords: DECT, limited-angular range, directional total variation, two-orthogonal-arc
DOI: 10.3233/XST-210974
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 6, pp. 975-985, 2021
Authors: Shamul, Naomi | Joskowicz, Leo
Article Type: Research Article
Abstract: BACKGROUND: Detecting and interpreting changes in the images of follow-up CT scans by the clinicians is often time-consuming and error-prone due to changes in patient position and non-rigid anatomy deformations. Thus, reconstructed repeat scan images are required, precluding reduced dose sparse-view repeat scanning. OBJECTIVE: A method to automatically detect changes in a region of interest of sparse-view repeat CT scans in the presence of non-rigid deformations of the patient’s anatomy without reconstructing the original images. METHODS: The proposed method uses the sparse sinogram data of two CT scans to distinguish between genuine changes in the repeat …scan and differences due to non-rigid anatomic deformations. First, size and contrast level of the changed regions are estimated from the difference between the scans’ sinogram data. The estimated types of changes in the repeat scan help optimize the method’s parameter values. Two scans are then aligned using Radon space non-rigid registration. Rays which crossed changes in the ROI are detected and back-projected onto image space in a two-phase procedure. These rays form a likelihood map from which the binary changed region map is computed. RESULTS: Experimental studies on four pairs of clinical lung and liver CT scans with simulated changed regions yield a mean changed region recall rate > 86%and a mean precision rate > 83%when detecting large changes with low contrast, and high contrast changes, even when small. The new method outperforms image space methods using prior image constrained compressed sensing (PICCS) reconstruction, particularly for small, low contrast changes (recall = 15.8%, precision = 94.7%). CONCLUSION: Our method for automatic change detection in sparse-view repeat CT scans with non-rigid deformations may assist radiologists by highlighting the changed regions and may obviate the need for a high-quality repeat scan image when no changes are detected. Show more
Keywords: 3D Radon space, low-dose sparse repeat CT scanning, non-rigid transformation, repeat scan change detection
DOI: 10.3233/XST-211040
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 6, pp. 987-1007, 2021
Authors: Yang, Shuo | Bie, Yifan | Pang, Guodong | Li, Xingchao | Zhao, Kun | Zhang, Changlei | Zhong, Hai
Article Type: Research Article
Abstract: OBJECTIVE: To assess clinical application of applying deep learning image reconstruction (DLIR) algorithm to contrast-enhanced portal venous phase liver computed tomography (CT) for improving image quality and lesions detection rate compared with using adaptive statistical iterative reconstruction (ASIR-V) algorithm under routine dose. METHODS: The raw data from 42 consecutive patients who underwent contrast-enhanced portal venous phase liver CT were reconstructed using three strength levels of DLIRs (low [DL-L]; medium [DL-M]; high [DL-H]) and two levels of ASIR-V (30%[AV-30]; 70%[AV-70]). Objective image parameters, including noise, signal-to-noise (SNR), and the contrast-to-noise ratio (CNR) relative to muscle, as well as subjective …parameters, including noise, artifact, hepatic vein-clarity, index lesion-clarity, and overall scores were compared pairwise. For the lesions detection rate, the five reconstructions in patients who underwent subsequent contrast-enhanced magnetic resonance imaging (MRI) examinations were compared. RESULTS: For objective parameters, DL-H exhibited superior image quality of lower noise and higher SNR than AV-30 and AV-70 (all P < 0.05). CNR was not statistically different between AV-70, DL-M, and DL-H (all P > 0.05). In both objective and subjective parameters, only image noise was statistically reduced as the strength of DLIR increased compared with ASIR-V (all P < 0.05). Regarding the lesions detection rate, a total of 45 lesions were detected by MRI examination and all five reconstructions exhibited similar lesion-detection rate (25/45, 55.6%). CONCLUSION: Compared with AV-30 and AV 70, DLIR leads to better image quality with equal lesion detection rate for liver CT imaging under routine dose. Show more
Keywords: Deep learning image reconstruction (DLIR), Adaptive statistical iterative reconstruction (ASIR-V), Image quality evaluation, Computed tomography (CT)
DOI: 10.3233/XST-210953
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 6, pp. 1009-1018, 2021
Authors: Abdullah, Chaymaa | Farag, Hamed | El-Sheshtawy, Wael | Aboelenein, Hassan | Guirguis, O.W.
Article Type: Research Article
Abstract: OBJECTIVE: To evaluate dose differences predicted between using Anisotropic Analytical Algorithm (AAA) and Acuros XB (AXB) in patients diagnosed with locally advanced non-small cell lung cancer (NSCLC) treated with intensity modulated radiation therapy (IMRT). METHODS: A phantom study was done to evaluate the dose prediction accuracy of AXB and AAA beyond low-density medium by comparing the calculated measurement results. Thirty-two advanced NSCLC patients were subjected to IMRT. The dose regimen was 60 Gy over 30 fractions. Effects on planning target volume (PTV) and organ-at-risk (OAR) were evaluated. Clinically acceptable treatment plans with AAA were re-calculated using AXB algorithms with …two modes Dw and Dm at the same beam arrangements and multileaf collimator leaf settings as with AAA. RESULTS: Using AXB yielded better agreement with the measurements and the average dose difference for all points was about 0.5%. Conversely, using AAA showed a larger disagreement with measured values and the average difference was up to 5.9%. The maximum relative difference was between AXB_Dm and AAA for PTV dose (D98 % ). The percentage dose differences of plans calculated by AAA, AXB_Dw and AAA, AXB_Dm revealed that AAA overestimated the dose than AXB. Regarding OAR, results showed significant difference for lungs-PTV. CONCLUSIONS: AXB algorithm yields more accurate dose prediction than AAA in heterogeneous medium. Differences in dose distribution are observed when plans re-calculated with AXB indicating that AAA apparently overestimates dose, particularly the PTV dose. Thus, AXB algorithm should be used in preference to AAA for cases in which PTVs are involved with tissues of highly different densities, such as lung. Show more
Keywords: Anisotropic analytical algorithm (AAA), Acuros XB (AXB), non-small cell lung cancer (NSCLC), intensity modulated radiation therapy (IMRT)
DOI: 10.3233/XST-210942
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 6, pp. 1019-1031, 2021
Authors: Iqbal, Muhammad Asad | Wang, Xian | Guoliang, Zhang | Moazzam, Nida Fatima | Shahid, Ahmad Daniyal | Qian, Xiaoqin | Qian, Wei
Article Type: Research Article
Abstract: OBJECTIVE: To compare and evaluate diagnostic capabilities of preoperative ultrasonography (US) and magnetic resonance imaging (MRI) in the cervical lymph nodes of patients with papillary thyroid cancer. METHODS: A retrospective dataset involving 156 patients who had undergone thyroidectomy and preoperative US and MRI was assembled. Among these, 69 had cervical lymph node metastasis and 87 did not. At least four radiologists unilaterally and spontaneously investigated the US and MRI attributes of the cervical lymph nodes. The efficiency of diagnostic imaging for cervical lymph nodes, including their true-positive rate or sensitivity, true-negative rate or specificity, positive predictive value, negative …predictive value, and predictive accuracy were analysed and assessed. RESULTS: In the assessment of cervical lymph node metastases of papillary thyroid cancer, the diagnostic sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of diagnostic US vs. MRI were 58.0% vs. 79.7%, 69.0% vs. 83.9%, 59.7% vs. 79.7%, 67.4% vs. 83.9%, and 64.1% vs. 82.1%, respectively. The accuracy consistency of the two imaging modalities was 83.5%. CONCLUSIONS: MRI is more effective than US in diagnosing and assessing cervical lymph node metastases of papillary thyroid cancer. Show more
Keywords: Magnetic resonance imaging (MRI), ultrasound imaging (US), cervical lymph node, thyroid cancer, comparison between MRI and US
DOI: 10.3233/XST-210927
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 6, pp. 1033-1044, 2021
Authors: Shi, Lei | Qu, Gangrong
Article Type: Research Article
Abstract: BACKGROUND: The limited-angle reconstruction problem is of both theoretical and practical importance. Due to the severe ill-posedness of the problem, it is very challenging to get a valid reconstructed result from the known small limited-angle projection data. The theoretical ill-posedness leads the normal equation AT Ax = AT b of the linear system derived by discretizing the Radon transform to be severely ill-posed, which is quantified as the large condition number of AT A . OBJECTIVE: To develop and test a new valid algorithm for improving the limited-angle image reconstruction with the …known appropriately small angle range from [ 0 , π 3 ] ∼ [ 0 , π 2 ] . METHODS: We propose a reweighted method of improving the condition number of AT Ax = AT b and the corresponding preconditioned Landweber iteration scheme. The weight means multiplying AT Ax = AT b by a matrix related to AT A , and the weighting process is repeated multiple times. In the experiment, the condition number of the coefficient matrix in the reweighted linear system decreases monotonically to 1 as the weighting times approaches infinity. RESULTS: The numerical experiments showed that the proposed algorithm is significantly superior to other iterative algorithms (Landweber, Cimmino, NWL-a and AEDS) and can reconstruct a valid image from the known appropriately small angle range. CONCLUSIONS: The proposed algorithm is effective for the limited-angle reconstruction problem with the known appropriately small angle range. Show more
Keywords: Landweber iteration, limited-angle image reconstruction, condition number
DOI: 10.3233/XST-210936
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 6, pp. 1045-1063, 2021
Authors: Yang, Tiejun | Cui, Xiaojuan | Bai, Xinhao | Li, Lei | Gong, Yuehong
Article Type: Research Article
Abstract: BACKGROUND: Convolutional neural network has achieved a profound effect on cardiac image segmentation. The diversity of medical imaging equipment brings the challenge of domain shift for cardiac image segmentation. OBJECTIVE: In order to solve the domain shift existed in multi-modality cardiac image segmentation, this study aims to investigate and test an unsupervised domain adaptation network RA-SIFA, which combines a parallel attention module (PAM) and residual attention unit (RAU). METHODS: First, the PAM is introduced in the generator of RA-SIFA to fuse global information, which can reduce the domain shift from the respect of image alignment. Second, …the shared encoder adopts the RAU, which has residual block based on the spatial attention module to alleviate the problem that the convolution layer is insensitive to spatial position. Therefore, RAU enables to further reduce the domain shift from the respect of feature alignment. RA-SIFA model can realize the unsupervised domain adaption (UDA) through combining the image and feature alignment, and then solve the domain shift of cardiac image segmentation in a complementary manner. RESULTS: The model is evaluated using MM-WHS2017 datasets. Compared with SIFA, the Dice of our new RA-SIFA network is improved by 8.4%and 3.2%in CT and MR images, respectively, while, the average symmetric surface distance (ASD) is reduced by 3.4 and 0.8mm in CT and MR images, respectively. CONCLUSION: The study results demonstrate that our new RA-SIFA network can effectively improve the accuracy of whole-heart segmentation from CT and MR images. Show more
Keywords: Cardiac image segmentation, domain shift, multi-modality, domain adaptation
DOI: 10.3233/XST-210966
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 6, pp. 1065-1078, 2021
Authors: Gong, Changcheng | Zeng, Li
Article Type: Research Article
Abstract: Limited-angle computed tomography (CT) may appear in restricted CT scans. Since the available projection data is incomplete, the images reconstructed by filtered back-projection (FBP) or algebraic reconstruction technique (ART) often encounter shading artifacts. However, using the anisotropy property of the shading artifacts that coincide with the characteristic of limited-angle CT images can reduce the shading artifacts. Considering this concept, we combine the anisotropy property of the shading artifacts with the anisotropic structure property of an image to develop a new algorithm for image reconstruction. Specifically, we propose an image reconstruction method based on adaptive weighted anisotropic total variation (AwATV). This …method, termed as AwATV method for short, is designed to preserve image structures and then remove the shading artifacts. It characterizes both of above properties. The anisotropy property of the shading artifacts accounts for reducing artifacts, and the anisotropic structure property of an image accounts for preserving structures. In order to evaluate the performance of AwATV, we use the simulation projection data of FORBILD head phantom and real CT data for image reconstruction. Experimental results show that AwATV can always reconstruct images with higher SSIM and PSNR, and smaller RMSE, which means that AwATV enables to reconstruct images with higher quality in term of artifact reduction and structure preservation. Show more
Keywords: Computed tomography (CT), CT image reconstruction, inverse problem, anisotropic total variation
DOI: 10.3233/XST-210954
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 6, pp. 1079-1102, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl