Article type: Research Article
Authors: Chen, Buxina | Zhang, Zhenga | Xia, Dana | Sidky, Emil Y.a | Pan, Xiaochuana; b; *
Affiliations: [a] Department of Radiology, The University of Chicago, Chicago, IL, USA | [b] Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, IL, USA
Correspondence: [*] Corresponding author: X. Pan. Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, IL 60637, USA. E-mail: xpan@uchicago.edu.
Abstract: BACKGROUND:Interest exists in dual-energy computed tomography (DECT) imaging with scanning arcs of limited-angular ranges (LARs) for reducing scan time and radiation dose, and for enabling scan configurations of C-arm CT that can avoid possible collision between the rotating X-ray tube/detector and the imaged subject. OBJECTIVE:In this work, we investigate image reconstruction for a type of configurations of practical DECT interest, referred to as the two-orthogonal-arc configuration, in which low- and high-kVp data are collected over two non-overlapping arcs of equal LAR α, ranging from 30° to 90°, separated by 90°. The configuration can readily be implemented, e.g., on CT with dual sources separated by 90° or with the slow-kVp-switching technique. METHODS:The directional-total-variation (DTV) algorithm developed previously for image reconstruction in conventional, single-energy CT is tailored to enable image reconstruction in DECT with two-orthogonal-arc configurations. RESULTS:Performing visual inspection and quantitative analysis of monochromatic images obtained and effective atomic numbers estimated, we observe that the monochromatic images of the DTV algorithm from LAR data are with substantially reduced LAR artifacts, which are observed otherwise in those of existing algorithms, and thus visually correlate reasonably well, in terms of metrics PCC and nMI, with their reference images obtained from full-angular-range data. In addition, effective atomic numbers estimated from LAR data of DECT with two-orthogonal-arc configurations are in reasonable agreement, with relative errors up to ∼ 10%, with those estimated from full-angular-range data in DECT. CONCLUSIONS:The results acquired in the work may yield insights into the design of LAR configurations of practical dual-energy application relevance in diagnostic CT or C-arm CT imaging.
Keywords: DECT, limited-angular range, directional total variation, two-orthogonal-arc
DOI: 10.3233/XST-210974
Journal: Journal of X-Ray Science and Technology, vol. 29, no. 6, pp. 975-985, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl