Bio-Medical Materials and Engineering - Volume 24, issue 6
Purchase individual online access for 1 year to this journal.
Price: EUR 245.00
Impact Factor 2024: 1.0
The aim of
Bio-Medical Materials and Engineering is to promote the welfare of humans and to help them keep healthy. This international journal is an interdisciplinary journal that publishes original research papers, review articles and brief notes on materials and engineering for biological and medical systems.
Articles in this peer-reviewed journal cover a wide range of topics, including, but not limited to: Engineering as applied to improving diagnosis, therapy, and prevention of disease and injury, and better substitutes for damaged or disabled human organs; Studies of biomaterial interactions with the human body, bio-compatibility, interfacial and interaction problems; Biomechanical behavior under biological and/or medical conditions; Mechanical and biological properties of membrane biomaterials; Cellular and tissue engineering, physiological, biophysical, biochemical bioengineering aspects; Implant failure fields and degradation of implants. Biomimetics engineering and materials including system analysis as supporter for aged people and as rehabilitation; Bioengineering and materials technology as applied to the decontamination against environmental problems; Biosensors, bioreactors, bioprocess instrumentation and control system; Application to food engineering; Standardization problems on biomaterials and related products; Assessment of reliability and safety of biomedical materials and man-machine systems; and Product liability of biomaterials and related products.
Abstract: This paper describes a study dealing with a technological solution to measure gait quality in people suffering from multiple sclerosis (MS) by selecting objective parameters that focus on their step. Android mobile technology, online services and four wireless pressure sensors are used in concert for this purpose. The objective of this work is the early detection of deterioration of the patient so that a physician can quickly intervene. Tests were carried out on a group of 8 persons with MS, and these results were compared with a control a group of 6 healthy participants. The results indicated a statistical difference…in 7 of 40 general step features, with a minimum σ=0.013 and a maximum σ=0.029. These characteristics showed differences between first and fifth metatarsals for each group. It was concluded that these parameters can be used to evaluate gait degeneration in people with MS and that further information could be obtained from measurements with sensors to monitor activities such as bending and inertial sensors.
Show more
Abstract: This paper presents a shoe-integrated sensor device which collects objective information concerning the gait quality in patients' physical rehabilitation. It involves four pressure sensors, two bending sensors, an ultrasonic sensor and a 9dof IMU, an Inertial Measurement Unit with three accelerometers, three gyroscopes and three magnetometers. The device includes a SDRAMPS with the aim of storing the information for long periods of time. The collected data can be sent to the server for later visualization by the specialist and the patient on a web platform. An interface shows the data in real time, allowing it to verify the connections and…to check different movements.
Show more
Abstract: Promising development in the light emitting diode (LED) technology has spurred the interest to adapt LED for both illumination and data transmission. This has fostered the growth of interest in visible light communication (VLC), with on–going research to utilize VLC in various applications. This paper presents a mobile–health monitoring system, where healthcare information such as biomedical signals and patient information are transmitted via the LED lighting. A small and portable receiver module is designed and developed to be attached to the mobile device, providing a seamless monitoring environment. Three different healthcare information including ECG, PPG signals and HL7 text information…is transmitted simultaneously, using a single channel VLC. This allows for a more precise and accurate monitoring and diagnosis. The data packet size is carefully designed, to transmit information in a minimal packet error rate. A comprehensive monitoring application is designed and developed through the use of a tablet computer in our study. Monitoring and evaluation such as heart rate and arterial blood pressure measurement can be performed concurrently. Real–time monitoring is demonstrated through experiment, where non–hazardous transmission method can be implemented alongside a portable device for better and safer healthcare service.
Show more
Abstract: Recently, several medical devices that use wireless communication are under development. In this paper, the small size frequency shift keying (FSK) transmitter and a monofilar antenna for the capsule endoscope, enabling the medical device to transmit VGA-size images of the intestine. To verify the functionality of the proposed wireless communication system, computer simulations and animal experiments were performed with the implemented capsule endoscope that includes the proposed wireless communication system. Several fundamental experiments are carried out using the implemented transmitter and antenna, and animal in-vivo experiments were performed to verify VGA image transmission.
Abstract: This paper presents the results of research that applies cognitive therapies associated with memory and mathematical problem-solving in elderly people. The exercises are programmed in an iPad and can be performed both from the Tablet and in an interactive format with a LEGO robot. The system has been tested with 2 men and 7 women over the age of 65 who have slight physical and cognitive impairment. Evaluation with the SUS resulted in a mean of 48.45 with a standard deviation of 5.82. The score of overall satisfaction was 84.37 with a standard deviation of 18.6. Interaction with the touch…screen caused some usability problems due to the elderly people's visual difficulties and clicking accuracy. Future versions will include visualization with more color contrast and less use of the keyboard.
Show more
Keywords: iPad, cognitive rehabilitation, objective-C, system usability scale (SUS)
Abstract: The discrete-time fractional Gaussian noise (DFGN) has been proven to be a regular process. Therefore, an autoregressive (AR) model of an infinite order can describe DFGN based on Wold and Kolmogorov theorems. A fast estimation algorithm on the Hurst exponent of DFGN or discrete-time fractional Brownian motion (DFBM) has been proposed, but the algorithm did not consider the order selection of AR model. Recently, a Hurst exponent estimator based on an AR model with six existing methods of order selection has been proposed to raise the accuracy of estimating the Hurst exponent. Although the estimation accuracy has been confirmed to…be better than the one without order selection, the estimator still requires computing all parameter sets through the Levinson algorithm. In order to lower computational cost, this paper proposes an efficient method of order selection, simply called data induction, which uses simulation data to induce an appropriate threshold of terminating the Levinson algorithm before computing all parameter sets. Experimental results show that the proposed data-induction method has a competitive advantage over six existing methods of order selection in terms of lowering computational cost and raising the accuracy.
Show more
Abstract: This paper presents the single channel speech enhancement system using subband Kalman filtering by estimating optimal Autoregressive (AR) coefficients and variance for speech and noise, using Weighted Linear Prediction (WLP) and Noise Weighting Function (NWF). The system is applied for normal and Oesophageal speech signals. The method is evaluated by Perceptual Evaluation of Speech Quality (PESQ) score and Signal to Noise Ratio (SNR) improvement for normal speech and Harmonic to Noise Ratio (HNR) for Oesophageal Speech (OES). Compared with previous systems, the normal speech indicates 30% increase in PESQ score, 4 dB SNR improvement and OES shows 3 dB HNR…improvement.
Show more
Keywords: Kalman filter, autoregressive, speech enhancement, weighted linear prediction
Abstract: Biomedical magnetic induction measurement is a promising method for the detection of intracerebral hemorrhage (ICH), especially in China. Aiming at overcoming the problem of low sensitivity, a magnetic induction sensor is chosen to replace the conventional sensors. It uses a two-arm Archimedean spiral coil as the exciter and a circular coil as the receiver. In order to carry out high-fidelity simulations, the Chinese head model with real anatomical structure is introduced into this novel sensor for the first time. Simulations have been carried out upon early stage ICH measurements. By calculating the state sensitivity and time sensitivity of the perturbation…phase of two types of sensors using the electromagnetic software, we conclude that the primary signal received can be largely reduced using the novel sensor, which could effectively increase the time and state sensitivity simultaneously.
Show more
Keywords: Intracerebral hemorrhage (ICH), magnetic induction measurement, sensor sensitivity, two-arm archimedean spiral coil (TAASC), Chinese head model
Abstract: This paper proposes a bio-potential measurement apparatus including a wireless device for transmitting acupuncture bio-potential information to a remote control station for health conditions analysis and monitor. The key technology of this system is to make replaceable foam-rubber cushions, double-side conducting tapes, chip and antenna on the radio frequency identification (RFID) tag. The foam-rubber cushions can be wetted with salt-water and contact with the acupuncture points to reduce contact resistance. Besides, the double-side conducting tapes are applied to fix foam-rubber cushions. Thus, one can peel the used cushions or tapes away and supply new ones quickly. Since the tag is…a flexible plastic substrate, it is easy to deploy on the skin. Besides, the amplifier made by CMOS technology on RFID chip could amplify the signals to improve S/N ratio and impedance matching. Thus, cloud server can wirelessly monitor the health conditions. An example shows that the proposed system can be used as a wireless health condition monitor, the numerical method and the criteria are given to analyze eleven bio-potentials for the important acupunctures of eleven meridians on a person's hands and legs. Then a professional doctor can know the performance of an individual and the cross-linking effects of the organs.
Show more
Keywords: RFID tag, bio-potential, flexible substrate, wireless health monitor, wetted replaceable foam-rubber cushion
Abstract: The piezoelectric biosensor have been widely used in ultra-small mass detection of biomolecular, based on PZT piezoelectric material can create a variety of compositions geometrically; it could widely develop a high-frequency resonator and measure the change of the slightest mass while improve the limited detection simultaneously. Therefore, the piezoelectric biosensor of this study was fabricated by a spin-coating method and backside etching process for improving the characteristic of piezoelectric biosensor. The result exhibited that the 250 μm × 250 μm working size has the most favorable piezoelectric characteristic. The tunability was approximately 38.56 % and it showed that reducing the…substrate thickness could obtain a clear resonance signal in a range of 60 to 380 MHz. In theory calculated for gravimetric sensing, it could achieve 0.1 ng sensing sensitivity. In gravimetric sensing, the sensing range was between 50,000~100,000 CFU/ml. Sensing range was lower in clinical urinary tract infection (100,000 CFU/ml), thus demonstrating its usefulness for preventive medicine. It can understand the piezoelectric sensor of this study has potential application in the future for biomedical gravimetric sensing.
Show more
Keywords: Lead zirconate titanate (PZT), piezoelectric, biosensor, resonance-frequency, escherichia coli (E. coli)