Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: TBI and Aging
Guest editors: Wayne A. Gordon
Article type: Research Article
Authors: Jo, Hae Mina | Song, Jun-chanb | Jang, Sung Hoa; *
Affiliations: [a] Department of Physical Medicine and Rehabilitation, College of Medicine, Yeungnam University, Namku, Taegu, Republic of Korea | [b] Department of Physical Therapy, Daegu Health College, Daegu, Republic of Korea
Correspondence: [*] Address for correspondence: Sung Ho Jang, Department of Physical Medicine and Rehabilitation, College of Medicine, Yeungnam University 317-1, Daemyungdong, Namku, Taegu, 705-717, Republic of Korea. Tel.: +82 53 620 3269; Fax: +82 53 620 3269; E-mail: strokerehab@hanmail.net
Abstract: We investigated the effect of a static stretching device on spasticity and motor function for people with chronic hemiparesis following stroke. Ten participants with chronic hemiparesis following stroke who had severe spasticity and incomplete weakness of the affected wrist and hand were recruited. The stretching device consisted of a resting hand splint, a finger and thumb stretching system, and a frame. The stretched state was maintained for 10 minutes/session, and the static stretching program was performed for 2 sessions/day and 7 days/week for 4 weeks. Spasticity and motor function of the affected wrist and hand were assessed three times with intervals of 4 weeks (twice [Pre-1, Pre-2] before and once [Post-1] after starting the static stretching program). The effect of the static stretching device was assessed using modified Ashworth scale (MAS) scores, by measuring active range of motion (AROM), and using the wrist and hand subsection of the Fugl-Meyer motor assessment (FMA). The main effects of the static stretching program on MAS scores for wrist and metacarpophalangeal (MCP) joints and FMA scores were significant. AROMs of MCPs and wrist showed an increase, however, no significant main effects of the static stretching program were observed. MAS in flexor muscles of MCP joints showed a significant decreased from Pre-2 (mean ± standard deviation (SD): 2.56 ± 0.55; median and interquartile range (IQR): 2.42, 2.12–3.08) to Post-1 (mean ± SD: 1.05 ± 0.49; median and IQR: 1.08, 0.87–1.50) (P < 0.001), and MAS in wrist flexor muscles also showed a significant decrease from Pre-2 (mean ± SD: 3.20 ± 0.78; median and IQR: 3.0, 2.75–4.0) to Post-1 (mean ± SD: 1.90 ± 0.73; median and IQR: 2.0, 1.0–2.5) (P < 0.001). FMA score also showed a significant increase from Pre-2 (11.3 ± 6.09) to Post-1 (14.5 ± 6.20) (P < 0.001). It was found that the static stretching device effectively relieved spasticity and improved motor function in subjects with severe spasticity and incomplete weakness following stroke.
Keywords: Motor function, spasticity, stretch, hemiparesis, stroke
DOI: 10.3233/NRE-130857
Journal: NeuroRehabilitation, vol. 32, no. 2, pp. 369-375, 2013
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl