Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Fernandes, John F.T.* | Lamb, Kevin L. | Twist, Craig
Affiliations: Department of Sport and Exercise Sciences, University of Chester, UK
Correspondence: [*] Corresponding author: John Fernandes, Department of Sport and Exercise Sciences, University of Chester, Parkgate Road, Chester, CH1 4BJ, UK. Tel.: +44 01244 511988; E-mail:j.fernandes@chester.ac.uk
Abstract: BACKGROUND: The FitroDyne has been used to assess muscle function but its reproducibility has not been determined during traditional multi-jointed resistance exercises. OBJECTIVE: To assess the intra- and inter-day reproducibility of the FitroDyne during traditional resistance exercises. METHODS: Fourteen resistance trained males completed a one repetition maximum (1RM) and three repetitions of bench press, squat and bent-over-row in 10% increments (from 20 to 80%). Replica trials were completed two and 48 hours later. The FitroDyne rotary encoder measured barbell velocity during each repetition from which power output was calculated. RESULTS: For all loads and exercises the intra-day typical error (TE) for peak and mean power, and velocity, respectively, during bench press (8.2-53 W and 2.2-6.9 cm ⋅ s - 1), squat (13.3-55.6 W and 2.4-7.4 cm ⋅ s - 1), and bent-over-row (14.5-62.8 W and 4-10.5 cm ⋅ s - 1) identified only moderate changes. Bench press yielded poor intra-day reproducibility at 80% 1RM only (CV% = 12.2-17.1), whereas squat and bent-over-row across all loads for peak and mean power and velocity displayed better reproducibility CV% = 2.4-9.0). Inter-day, the TE detected moderate changes for peak and mean power and velocity for all three exercises. Inter-day reproducibility was comparable to intra-day, though improved for bench press 80% 1RM (CV% = 6.1-8.6). CONCLUSION: These data support the use of the FitroDyne at submaximal loads for monitoring moderate changes in muscle function both intra- and inter-day.
Keywords: Power, velocity, reliability, bench press, squat, bent-over-row
DOI: 10.3233/IES-150599
Journal: Isokinetics and Exercise Science, vol. 24, no. 1, pp. 39-49, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl