Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Brown, Lee E.a; *; ** | Whitehurst, Michaela; *** | Bryant, Jennifer R.a; ****
Affiliations: [a] American Med-Care Center and Rehabilitation Facility
Note: [*] Clinical Director, American Med-Care Center and Rehabilitation Facility, Palm Springs, FL.
Note: [**] Address reprint requests to Mr. Brown at South Palm Orthopedics, 16244 South Military Trail, Suite 590, Delray Beach, FL 33484.
Note: [***] Human Performance Laboratory, Florida Atlantic University, Boca Raton, FL.
Note: [****] Fitness Director, American Med-Care Center and Rehabilitation Facility, Palm Springs, FL.
Abstract: The purpose of this study was to compare the tibial control system (TCS) and sliding cuff (SC) lever arms in the strength parameters peak torque (PT), average work (AW), average power (AP), joint angle at peak torque (JA), and fatigue index (FI). Fifteen healthy subjects, with no history of knee pathology, performed three knee extension/flexion repetitions using the right leg at a velocity spectrum of 60, 180, 240, and 20 repetitions at 300 deg/sec for each lever arm. TCS and SC were randomly presented with 24 hours between conditions. Significance was set at p < 0.05. Paired t tests showed that the SC produced significantly greater PT, AW, and AP than the TCS during extension across velocities. Also, SC JA occurred significantly later in the range of motion across velocities, whereas FI was significantly greater for the SC than the TCS at 300 deg/sec. Paired t tests for flexion data indicated that the TCS produced significantly greater PT than the SC across velocities and greater AP at 60 deg/sec. The SC condition resulted in significantly greater AW and AP at 300 deg/sec only. The SC and TCS conditions did not differ for JA and FI across velocities. It was concluded that choice of lever arm significantly influenced the strength parameters examined in this study.
Keywords: LIDO sliding cuff, tibial control system, isokinetic assessment
DOI: 10.3233/IES-1992-2301
Journal: Isokinetics and Exercise Science, vol. 2, no. 3, pp. 101-109, 1992
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl