Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Demoulin, C.a | Grosdent, S.a | Debois, I.a | Mahieu, G.a | Maquet, D.a | Jidovsteff, B.a | Croisier, J.-L.a | Crielaard, J.M.a | Vanderthommen, M.a
Affiliations: [a] Department of Physical Medicine and Rehabilitation, University of Liege, 4000 Liege, Belgium
Note: [] Address for correspondence: C. Demoulin, University of Liege, ISEPK (B21), Allée des Sports 4, B-4000 Liege, Belgium. Tel.: +32 4 366 39 47; Fax: +32 4 366 29 01; E-mail: adepaifve@ulg.ac.be
Abstract: The purpose of this study was to investigate the inter-session, inter-tester and inter-site reproducibility of trunk muscle strength scores in flexion, extension, lateral flexion and rotation. Ten healthy students were tested on four apparatus with a 7–10 day break between sessions. The first two sessions were identical while the other two differed either by the tester or by the site. Furthermore, 10 patients with chronic low back dysfunction (CLBD) were assessed with the four apparatus, once only. For all tests, CV ranged from 3.4% to 7.6% and from 3.9% to 8.1% in the inter-session and inter-tester studies, respectively (p>0.05 except for inter-session reproducibility of trunk flexor strength). Peak torque (PT) was more variable from site to site with a CV ranging from 4.2% to 12.7%, particularly in extension and left lateral flexion (p< 0.05). No statistically significant difference in the strength ratios (flexion/extension, right/left lateral-flexion and right/left rotation) were found between sessions or testers (4.9% < CV < 9.7%. The inter-site reproducibility of ratios was lower. Comparison between the CLBD patients and the healthy subjects with regard to PT normalized to body weight indicated significantly decreased performance for the former except for flexion and rotation scores in males. We conclude that in the case of healthy subjects, inter-session and inter-tester trunk strength measurements derived from these devices are reproducible. The low inter-site reproducibility suggests that caution should be exercised when interpreting findings originating from different sites. The lower extension strength scores in CLBD patients test lends some validity to the system. However, further studies focusing on reproducibility and validity of this system in CLBD patients are critical before any conclusion regarding their clinical viability may be drawn.
Keywords: Trunk muscles, low back pain, isometric strength test, device reliability
DOI: 10.3233/IES-2006-0240
Journal: Isokinetics and Exercise Science, vol. 14, no. 4, pp. 317-325, 2006
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl