Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Special Issue on Tomography and Neuroscience
Guest editors: Sara Brunetti, Paolo Dulio, Andrea Frosini and Grzegorz Rozenberg
Article type: Research Article
Authors: Presotto, Luca; *
Affiliations: Nuclear Medicine Unit, IRCCS San Raffaele Scientific Institute, Milano, Italy. presotto.luca@hsr.it
Correspondence: [*] Address for correspondence: Nuclear Medicine Unit, IRCCS San Raffaele Scientific Institute, Via Olgettina, 60, 20132 Milano (MI), Italy
Abstract: Positron Emission Tomography image reconstruction needs a map of photon attenuation probability to provide the correct solution. This map is generally provided by an independent imaging modality. However, it might suffer for artifacts due to patient motion in sequential systems or from intrinsic limitation of the second modality (e.g.: bones that cannot be identified in MR images). It has been shown that such map can be estimated from the PET data themselves, but the solution to this problem has much worse conditioning than the tomographic problem. In this work we propose a new algorithm based on the use of multiple L1 regularization terms in the attenuation sub-problem, to incorporate prior knowledge. We also chose optimal maximizers for both sub-problems: preconditioned gradient descent for the emission one and split-Bregman for the attenuation one. The algorithm was then tested using digital phantom simulations. The proposed algorithm proved to provide accurate quantification over a large range of strength of the regularization terms. The algorithm is also able to reconstruct objects outside of the region where the problem is uniquely determined and it is able to fix the undetermined global scaling factor of joint attenuation and emission estimation. Thanks to the maximizers chosen, the algorithm is computationally less expensive than the current standard.
DOI: 10.3233/FI-2020-1900
Journal: Fundamenta Informaticae, vol. 172, no. 2, pp. 187-202, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl