Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Liggett, Walter S. | Barker, Peter E. | Semmes, O. John | Cazares, Lisa H.
Affiliations: Statistical Engineering Division and Biotechnology Division, National Institute of Standards and Technology, Gaithersburg, MD 20899, USA | Center for Biomedical Proteomics, Eastern Virginia Medical School, Norfolk, VA 23507, USA
Note: [] Corresponding author. Tel.: +1 301 975 2851; Fax: +1 301 990 4127; E-mail: walter.liggett@nist.gov
Abstract: Biomarker discovery and development requires measurement reproducibility studies in addition to case-control studies. Parallel pursuit of reproducibility studies is especially important for emerging technologies such as protein biomarkers based on time-of-flight mass spectrometry, the case considered in this paper. For parallel studies, a way to improve reproducibility prior to identification of protein species is necessary. One approach is use of functional principal components analysis (PCA) as the basis for assessing measurement reproducibility. Reproducibility studies involve repeated measurement of a reference material such as a human serum standard. Measurement in our example is by SELDI-TOF (surface-enhanced laser desorption and ionization time-of-flight) mass spectrometry. Reproducibility is defined in reference to a source of variation, which in our example is associated with a type of commercially available protein biochip. We obtained spectra for 8 spots on each 11 chips. Two spectra are generally more alike when obtained from the same chip rather than different chips. Thus, our experiment indicates potential improvements from reducing variation in chip manufacture and chip handling during measurement. Our analysis involves careful registration of the spectra and characterization of the spectral differences. As shown by our example, a metrological analysis may enhance case-control studies by guiding optimization of the measurements underlying the biomarker.
Journal: Disease Markers, vol. 20, no. 6, pp. 295-307, 2004
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl