Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Frontiers in Biomedical Engineering and Biotechnology – Proceedings of the 2nd International Conference on Biomedical Engineering and Biotechnology, 11–13 October 2013, Wuhan, China
Article type: Research Article
Authors: Huang, You-Min; | Chou, I-Chiang | Jiang, Cho-Pei | Wu, Yi-Syun | Lee, Shyh-Yuan
Affiliations: Department of Mechanical Engineering, National Taiwan University of Science & Technology, 43 Sec. 4, Keelung Rd., Taipei 106, Taiwan | Department of Dentistry in Taipei City Hospital, School of Dentistry in National Yang-Ming University, No.155, Sec.2, Linong Street, Taipei 112, Taiwan | Department of Power Mechanical Engineering, National Formosa University, 64, Wunhua Rd., Yunlin 632, Taiwan
Note: [] Corresponding Author: Prof. You-Min Huang Tel: +886-2-2737-6487Fax: +886-2-2737-6460; E-Mail: ymhuang@mail.ntust.edu.tw
Abstract: The purpose of this study is to investigate the effect of implant neck design and cortical bone thickness by means of 3-D linearly elastic finite element analysis and to analyze primary and secondary stability of clinical evidence based on micromotion and principal stress. Four commercial dental implants, comparable in size, for a type IV bone and mandibular segments were created. Various parameters were considered, including the osseointegration condition (non- and full bonded), force direction (vertical and horizontal) and cortical bone thickness (0.3, 0.5 and 1mm). The force was considered a static load applied at the top of the platform. The magnitudes of the vertical and horizontal loading direction were 500 N and 250 N. Micromotion and principal stresses were employed to evaluate the failure of osseointegration and bone overloading, respectively. The results show that Maximum stress of the peri-implant bone decreased as cortical bone thickness increased. The stress concentration regions were located at the implant neck between the cortical bone and cancellous bone. The micromotion level in full osseointegration is less than that in non-osseointegration and it also decreases as a increasing of cortical bone thickness. Consequently, cortical bone thickness is a key factor for primary stability.
Keywords: Dental, Neck, Osseointegration, Mandible
DOI: 10.3233/BME-130945
Journal: Bio-Medical Materials and Engineering, vol. 24, no. 1, pp. 1407-1415, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl