Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Imani, Rana | Rafienia, Mohammad; | Hojjati Emami, Shahriar
Affiliations: Biomaterial Group, Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran | Biosensor Research Center, Isfahan University of Medical Sciences, Isfahan, Iran
Note: [] Address for correspondence: Mohammad Rafienia, Biosensor Research Center, Isfahan University of Medical Sciences, Isfahan 817473461, Iran. E-mail: m_rafienia@med.mui.ac.ir
Abstract: In this study, preparation and characterization of soft crosslinked gelatin sponge for blood hemostasis application was considered. The effects of gelatin and crosslinker concentrations and altering freeze-drying temperature on sponges' density and structure, water absorption ability and biodegradation, cytotoxicity, mechanical properties and hemostatic effect were investigated. The density measurement indicated that the density of freeze-dried sponges increased when the freezing temperature was lowered. Scanning electron microscope and optical microscope images showed that gelatin sponges had uniform small pores (60 μm) after freezing at liquid nitrogen (−196°C). Biodegradation study demonstrated that the crosslinked sponges containing 1% and 2% gelatin lost respectively nearly 40 to 70% of their weight during 24 h. Prepared sponges showed desired water absorption ability (30–40 times of own dry weight) improved by lowering glutaraldehyde concentration. Cell toxicity was not detected in any of the samples. Compression modulus of sponges decreased four times (160 to 40 kPa) as the gelatin content varied from 2 to 1% w/v. Hemostasis study confirmed that the hemolytic ability of sponges increased through raising gelatin content and porosity of sponge. We suggest using gelatin sponges containing 1% w/v gelatin, 0.5% w/v glutaraldehyde frozen in liquid nitrogen, as a potential substitution for local hemostat absorbable sponge.
Keywords: Gelatin, glutaraldehyde, hemostat sponge, bioabsorbability
DOI: 10.3233/BME-130745
Journal: Bio-Medical Materials and Engineering, vol. 23, no. 3, pp. 211-224, 2013
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl